F17 - Insufficient Water Flow; Figure 001-19: Pressure Pump - Miele CM6 Technical Information

Countertop coffee systems
Hide thumbs Also See for CM6:
Table of Contents

Advertisement

CM6
Technical Information

Figure 001-19: Pressure Pump

3. Insert the full pressure pump into the water tank receptacle.
4. Activate the water pump in service mode (see Section 001-4.4) and use it
to push water through the system.
Cause:
Wiring short-circuited or hoses clogged or kinked.
Remedy:
1. Check wiring and hoses.
Warning!
In order to avoid possible water system faults (e.g., clogging or blocking of
valves), grease, oil or other slip lubricants should never be used when
assembling and installing water system parts.
2. Replace wiring or hoses as necessary.
Cause:
Water tank valve jammed or clogged.
Remedy:
1. Check the water tank valve.
2. Replace the water tank, if necessary.
Cause:
Flow meter jammed or defective.
Remedy:
Replace the flow meter; see Section 001-4.16.
Cause:
Water pump defective.
Remedy:
Replace the water pump; see Section 001-4.15.
3.4

F17 - Insufficient Water Flow

Symptom:
Less than five pulses at flow meter input within a 6-second interval.
Cause:
Water tank not inserted correctly.
Remedy:
Insert water tank correctly.
Cause:
Appliance has stood for too long. Water pump has run dry.
23

Advertisement

Table of Contents
loading

Table of Contents