Remote Anomaly Code; Flue Probe - Biasi Inovia 16S User Manual

Table of Contents

Advertisement

16 (increase) keys. In order to exit the
INFO mode, hold keys 12 and 16 (Fig. 3.5)
pressed at the same time.
The table summarises the possible values
visible in INFO mode.
Value visualised
Primary circuit pressure
External temperature
K curve value configured
in loco
Offset climatic curve value
Calculated
heating
point (with climatic curve
or set configured)
Temperature NTC delivery
Temperature NTC return
Domestic set
Temp.
d.h.w.
inlet
foreseen)
Temp. d.h.w. output
D.h.w. capacity
Flue
temperature
foreseen)
Fan speed (if foreseen)
Pressure
transducer
pressure (if foreseen)
Ionization value
Number
of
months
maintenance
3 star status
(ON=01, OFF=00)
HWCH
Hardware
high
HWCL Hardware code low
SWCH Software code high
SWCL Software code low
USEFUL ADVICE
Index
J00 + value
J01 + value
J02 + value
J03 + value
set
J04 + value
J05 + value
J06 + value
----
(if
----
----
----
(if
J11 + value
J12 + value
J13 + value
J14 + value
to
J15 + value
----
code
J17 + value
J18 + value
J19 + value
J20 + value
3.8

Remote anomaly code

If the boiler is connected to remote (option-
al), a code that indicates a boiler anomaly is
displayed in the centre of the display.
The anomaly in progress is indicated by a
numeric code followed by the letter E.
The table summarises the possible codes
displayed on the remote.
Anomaly
Lack of burner ignition
Safety thermostat lockout
General lockout
Lack of circulation pump
Faulty fan control system / air
pressure / flue thermostat
Faulty c.h. temp. probe NTC1
or NTC2
Faulty external temp. probe
NTC (with K set)
Flame detection error
Lack of circulation T >105°C
3.9

Flue probe

The flue probe 20 and safety thermal fuse
26 indicated in Fig. 3.7 are a safety device.
The flue probe 20 intervenes when the flue
temperature exceeds 110°C placing the
boiler in safety block switching it off.
To reset normal boiler functioning, just press
the 13 (Fig. 3.5) key.
If flue probe 20 does not intervene and,
therefore does not send the boiler into se-
curity lockout, thermofusible 26 enters into
function as a further safety measure.
This component sends the boiler into se-
curity lockout when the flue temperature
reaches 167°C.
Code
E01
E02
E03
E04
E05
E06
E08
E11
E14
- 25 -