The Autotest Report

With CableManager software you can upload reports to a PC for viewing and
printing. The CableManager appendix in this manual shows examples of complete
Autotest reports for twisted pair cable.
You can send Autotest reports directly to a serial printer or edit the report's
identification information in the PRINT mode. See Chapter 5, "Viewing and
Printing Saved Reports," for complete instructions.
The overall result printed on a report can be a pass or fail, or warning. A failure of
any test required by the selected test standard produces a fail result on the report
summary. If required by the selected standard, a warning appears on reports for
twisted pair cable if a length, impedance, propagation delay, or delay skew test
produced a warning. The warning means that the measurement exceeds its limit,
but the test standard does not fail the cable based on that measurement.