Length
Range
Resolution
Accuracy
+ 2 % of reading)
Specifications are relative to calibrated value using a representative
reference cable. Variations occur because of variations in the cable
manufacturing process.
Propagation Delay
Range
Resolution
Accuracy
Delay Skew
Range
Resolution
Accuracy
DC Loop Resistance Test
Range: 0 Ω to 400 Ω
Accuracy: ±(2 Ω +2 % of reading)
Resolution: 0.1 Ω
Overload recovery time: Less than 10 minutes to rated accuracy following an
overvoltage. Self-calibration is required after repeated or prolonged overvoltage.
8-12
Twisted Pair Cable
0 ft to 328 ft
328 ft to 2500 ft
(0 m - 100 m)
(100 m - 762 m)
1 ft or 0.1 m
1 ft or 0.1 m
± (1 ft (0.3 m)
± (1 ft (0.3 m)
+ 4 % of reading)
Twisted Pair Cable
0 ns to 500 ns
500 ns to 3800 ns
1 ns
±(5 ns + 2 % of
±(5 ns + 4 % of
reading)
0 ft to 328 ft
(0 -100 m)
1 ft or 0.1 m
± (1 ft (0.3 m)
+ 2 % of reading)
Note
0 ns to 500 ns
1 ns
±(5 ns + 2 % of
reading)
reading)
Twisted Pair Cable
0 ns to 100 ns
1 ns
± 10 ns
Coaxial Cable
328 ft to 4000 ft
(100 m - 1219 m)
1 ft or 0.1 m
± (1 ft (0.3 m)
+ 4 % of reading)
Coaxial Cable
500 ns to 6000 ns
1 ns
1 ns
±(5 ns + 4 % of
reading)