DSP-4000 Series
Users Manual
Cable Type
and
Termination
Twisted pair
with no
remote
Twisted pair
with remote
Coaxial cable
with no
terminator
Coaxial
Cable with
terminator
4-10
Table 4-3. Effects of Termination on HDTDR Results
Listed Results Show the Following
Displays the message No Remote
Detected. Results show the two
largest reflections greater than or equal
to 15%. The largest reflection probably
comes from the end of the cable, but is
not identified as the end.
Two largest reflections greater than or
equal to 15%. Largest reflection is
identified as the end of the cable.
Two largest reflections greater than or
equal to 10%. The largest reflection
comes from the end of the cable, but is
not identified as the end.
No Reflection reported for a
good cable. On a faulty cable, the test
reports the two largest reflections, but
does not identify end of cable.
Plotted Results Show the
Following
All reflections are shown.
All reflections are shown.
All reflections are shown. The
largest reflection comes from the
end of the cable.
All reflections are shown. The plot
will not show a reflection from the
terminated end.