Removing the Interlock Switch Assembly
1.
Remove the upper case. (Refer to Removing the Upper Case, on page 3-16.)
2.
Disconnect the interlock assembly cable from junction connector CN9 on the
Cl 17 MAIN board assembly.
3.
Remove the CBB (M4 x 10) screw securing the interlock switch assembly to
the lower case and remove the interlock switch assembly.
Figure 3-27. Removing the Interlock Switch Assembly
EPSON DFX-5000+ Service Manual
Disassembly and Assembly
3-25