forced-air cooling fan or the air-conditioner to keep the
temperature under 50 ℃.
the Sensor in the same conduit, otherwise the Sensor may be
damaged or malfunction due to induction. Be sure to wire the lines
of the Sensor separately from power lines or high-tension lines or
within an exclusive, shielded conduit.
Amplifier, make sure that the Amplifier operates normally and take
proper measures so that the power lines will not have a bad
influence on the operation of the Amplifier.
sure to ground the FG (frame ground) and G (ground) terminals
of the switching regulator. The Sensor may malfunction due to
switching noise that will be generated from the switching
regulator if these terminals are not grounded.
thickness and length of the wire are 0.3 mm
respectively.
on the bottom of the Amplifier into contact with other metals,
because the connector and the bottom-metal- screws of the
Amplifier are connected internally to 0-V terminal of the Amplifier.
made of ABS resin. Do not use any other organic solvent (paint
thinner, benzine or alcohol etc.) to clean the product.
turned on. If the Sensor and load are connected to separate power
supplies, be sure to turn on the Sensor first.
ON.
2
min. and 20 m max.