Omron F10-C20 Instruction Sheet page 14

Pattern matching sensor amplifier
Hide thumbs Also See for F10-C20:
Table of Contents

Advertisement

Measurement Item: PATT/PLN 
Whether measurement is patterned or plain is determined automatically by 
 
comparing the contrast with the background within the detection range. When 
teaching is finished, all the level indicators will light for 0.5 s, and the buzzer will 
sound twice.
Pattern Measurement
The deviation level will become high if the senseing object has a pattern. If the 
deviation level is htgher than the set level of measurement item selecton, 
pattern measurement will be performed.
Detection Range
A
The portion with the highest 
deviation is registered as a 
model.
The  set  level  of  measurement  item  selection  is  increased  or 
decreased  by  pressing  the  SELECT  buttons.  Adjust  the  level 
according  to  the  background  and  deviation.  The  level  is  factory-
set between 2 and 3. 
If  the  object  has  some  light-color  lines  or  light-color  patterns, 
pattern  measurement  may  be  performed.  In  this  case,  by 
increasing  the  set  level  of  measurement  item  selection,  plain 
measurement will be performed.
Note: Do not turn OFF the Sensor before the Sensor is  
          set to MONITOR mode, otherwise the teaching data will  
          be lost.
High
Automatic 
selection
Deviation
1
Low
Measurement item  
selection level
21
Plain Measurement
If the set level of measurement item selection is higher than the deviation  
 
level, plain 
measurement will be performed.
 
Plain Measurement with A.T.OFF
 
 
The  deviation  and  average
density in the  Teaching area
are registered.  
Detection Range
 
 
*) By another mode, it is possible to enlarge Detection Range.
Plain Measurement with A.T.ON
The  deviation  and  average  density  in   
the  area  enclosed by dotted lines are
 
registered. 
The
dotted
projected.
 
Detection Range
 
*) By another mode, it is possible to enlarge Detection Range.
The pattern is outside the Sensing area. 
 
Upper Detection Range
Detection Range
The
sensing
area
 
 
restricted  so  that  the
pattern
close  to  the
 
edge  will  not  influence
the
results
of
 
 
 
discrimination.
Teaching Area
The  deviation  and average  density  in
the  Teaching  area are  registered  in
 
the above example.
   
High
Deviation
1
Low
Measurement item  
selection level
 
High
Deviation
 
lines are not 
1
 
Low
Measurement item  
selection level
Teaching
is
performed  in  the Teaching
 
 
area. 
The  pattern close to the edge of
the
sensing  area
is
not
registered
 
 
 
 
 
  
a
model
because  such  a
is
 
 
 
 
 
 
not
be
always
located
in
area
and accurate measurement
 
 
be
performed. In
this
example,
object
 
 
 
 
deviation  level
in  the  area
the
dotted
line
is
small. Therefore, plain 
 
 
 
 
measurement
will
be performed.
 
 
22
as
 
  
pattern
may
 
the
sensing
cannot
 
 
the
 
 
enclosed
by

Advertisement

Table of Contents
loading

This manual is also suitable for:

F10-c25F10-c30F10-c35F10-c50F10-c55

Table of Contents