A.T.ON
WD
TMR
LINE
A.T.OFF NM
RS-232C
 /422
・Model Size
WD:Wide mode
NM:Normal mode
Normal mode
Detection Range: 
Teaching Area: 
Shows the range of 
Registers this range 
the detection area.
as the model.
Use wide mode if the pattern in one direction is comparatively long, e.g., a production date. 
The measuring time for wide mode, however, takes three times longer than Normal Mode, as the 
pattern is processed as three models instead of one.
All the DIP switch pins are set to OFF  
at the factory.
Wide mode
Teaching area: 
Divedes the 
pattern into three, 
and registers it as 
three models.
 
Model 1 
Model 2 
Model 3 
detection 
detection 
detection 
range
range
range
9
A.T.ON
WD
TMR
LINE
RS-232C
A.T.OFF NM
 /422
All the DIP switch pins are set to OFF  
at the factory.
OFF Delay Timer
TMR:Delays the output operation 
when the control output goes from 
ON to OFF(Default value is 40ms. 
Refer to the Operation Manual for 
the Unit for changing procedure).
No Marking:Timer OFF.
Matching/Not Matching
≠:
Output ON when object does 
not match registered model.
=:
Output ON when object  
 match registered model.
External Input 
(F10-C50/C55 only) 
LINE:
Executes external input in  
RUN mode via input line.
RS-232C/422:
Executes external 
input in RUN mode via serial 
communications.