Monitor Mode - Omron F10-C20 Instruction Sheet

Pattern matching sensor amplifier
Hide thumbs Also See for F10-C20:
Table of Contents

Advertisement

Change of Plain Measurement Detection Range Selection Mode
*Detection range at Plain Measurement 
Detection range at Plain Measurement is as following.
Mode 1 and 2 can be changed by the operation at the power supply input.
Plain Measurement detection range selection mode
Mode 1(Initial setting)
Detection range at    measurement 
 
becomes the same size as the 
Plain 
teaching area.
Measurement
  with A.T.OFF
 
 
Detection range  
(=Teaching area)
Detection range at measurement 
B
becomes the following dotted line 
Plain 
frame.
Measurement 
with A.T.ON
 
Detection range
Approx.4.0mm (F10- S30R)
Approx.2.0mm (F10- S15R)
Approx.0.7mm (F10- S05R)
Approx.6.4mm (F10- S50R)
Detection range becomes small when a pattern is in the end as the 
following figure.
When using F10 -C30/C35/C50/C55
When  switching  banks  setting  around  of  a  bank  to  switch  for  Plain  Measurement
detection  range  selection  mode  different  from  the  bank  causes Plain  Measurement  
detection  range  type  error.   Please  note  that  you  set  the  same  mode  as  a  bank  to
switch to around of the bank.
Mode 2
Detection can be enlarged.
It  becomes  the  following  dotted   
line frame. 
Detection Range
 
 
Approx.1.0mm (F10- S30R)
 
Approx.0.5mm (F10- S15R)
 
 
Approx.0.2mm (F10- S05R)
Approx.1.6mm (F10- S50R)
 
Detection can be enlarged.
It  becomes  the  following  dotted  line
frame.
Detection range
 
 
Approx.1.0mm (F10- S30R)
 
Approx.0.5mm (F10- S15R)
 
Approx.0.2mm (F10- S05R)
                                           
Approx.1.6mm (F10- S50R)
 
 
 
 
 
Detection range  
(=Teaching area)
 
23
5.2 MONITOR Mode
The Sensor operates in MONITOR mode for threshold level 
 
adjustments and desktop sample tests for object discrimination 
with no signal output. No external output operation signal or 
external input signal is accepted in MONITOR mode.
Pattern Measurement 
 
On the basis of the registered model, the level indicator 
 
indicates the degree of conformity of the sensing object.
Status indicators(F10-C20/C25) 
● 
Pattern 
measuremet
Status indicators(F10-C30/C35/C50/C55) 
● 
BANK/STATUS
Bank No.
1
Set the mode selector to MON.  
Measurement continues as long as the  
selector is set to MON. 
 
PATT
Degree of 
coformance 
with model
DEV
PLN
AVE
Press the Switch 
Display Item button
(Return to bank number 
display no operation is 
BANK/STATUS
performed for 5 seconds)
Pattern  
masurement
24
Closer to  
model 
in appearance
1
The  closer  to  the  model  in  ap-
pearance, the higher the level.
Not closer to  
model 
1
in appearance
If no sensing object is within the 
sensing area or if the sensing ob-
ject  is  greatly  different  from  the 
model. the level will be lower.