Change of Plain Measurement Detection Range Selection Mode
*Detection range at Plain Measurement
Detection range at Plain Measurement is as following.
Mode 1 and 2 can be changed by the operation at the power supply input.
Plain Measurement detection range selection mode
Mode 1(Initial setting)
Detection range at measurement
A
becomes the same size as the
Plain
teaching area.
Measurement
with A.T.OFF
Detection range
(=Teaching area)
Detection range at measurement
B
becomes the following dotted line
Plain
frame.
Measurement
with A.T.ON
Detection range
Approx.4.0mm (F10- S30R)
Approx.2.0mm (F10- S15R)
Approx.0.7mm (F10- S05R)
Approx.6.4mm (F10- S50R)
Detection range becomes small when a pattern is in the end as the
following figure.
When using F10 -C30/C35/C50/C55
When switching banks setting around of a bank to switch for Plain Measurement
detection range selection mode different from the bank causes Plain Measurement
detection range type error. Please note that you set the same mode as a bank to
switch to around of the bank.
Mode 2
Detection can be enlarged.
It becomes the following dotted
line frame.
Detection Range
Approx.1.0mm (F10- S30R)
Approx.0.5mm (F10- S15R)
Approx.0.2mm (F10- S05R)
Approx.1.6mm (F10- S50R)
Detection can be enlarged.
It becomes the following dotted line
frame.
Detection range
Approx.1.0mm (F10- S30R)
Approx.0.5mm (F10- S15R)
Approx.0.2mm (F10- S05R)
Approx.1.6mm (F10- S50R)
Detection range
(=Teaching area)
23
5.2 MONITOR Mode
The Sensor operates in MONITOR mode for threshold level
adjustments and desktop sample tests for object discrimination
with no signal output. No external output operation signal or
external input signal is accepted in MONITOR mode.
Pattern Measurement
On the basis of the registered model, the level indicator
indicates the degree of conformity of the sensing object.
Status indicators(F10-C20/C25)
●
Pattern
measuremet
Status indicators(F10-C30/C35/C50/C55)
●
BANK/STATUS
Bank No.
1
Set the mode selector to MON.
Measurement continues as long as the
selector is set to MON.
PATT
Degree of
coformance
with model
DEV
PLN
AVE
Press the Switch
Display Item button
(Return to bank number
display no operation is
BANK/STATUS
performed for 5 seconds)
Pattern
masurement
24
Closer to
8
model
in appearance
7
6
5
4
3
2
1
The closer to the model in ap-
pearance, the higher the level.
8
7
6
5
4
3
2
Not closer to
model
1
in appearance
If no sensing object is within the
sensing area or if the sensing ob-
ject is greatly different from the
model. the level will be lower.