You can set the guide light to always ON to turn ON the
guide light and execute synchronous measurement.
Press the UP selection button when in RUN mode to turn
ON and OFF the guide light.
While the guide light is being turned ON or OFF, the ENAB
signal is turned OFF, and no external inputs can be
received.
The OUTPUT signal is turned OFF when the UP selection
button is pressed.
Press and hold
ON
down the UP
OFF
selection
ON
OUTPUT
OFF
ON
ENAB
OFF
Guide light
ON
ON
:Lit
OFF
OFF
:Unit
0.7s max.
29
Bank Change Input
Please input the number of BANK to "BANK 1 to 3" input lines.
The relation of "BANK 1 to 3" and the number of BANK is shown as follows.
BANK No.
BANK 0
BANK 1
BANK 2
BANK Input 1
OFF
ON
OFF
BANK Input 2
OFF
OFF
ON
BANK Input 3
OFF
OFF
OFF
The measurement is finished, after CONT signal
input is OFF. And then F10 check the status of
other input signals, ex. BANK
ON
Change input.
CONT
OFF
ON
BANK1
〜
3
OFF
MAX 20ms
ON
ENAB
OFF
ON
Measuring
OUTPUT
OFF
BANK 3
BANK 4
BANK 5
BANK 6
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
Please restart the measurement process,
after confirming that the ENAB output is
ON.
The BANK Change Input is
ignored while measuring.
MAX 30ms
MAX 20ms
The measurement time depends
on the measurement mode.
MAX 60ms
During Changing BANK
The both ENAB and OUTPUT are off
while changing BANK.
30
BANK 7
ON
ON
ON
Measuring