Appliance Setup; Remove Fixed Glass Assembly; Remove The Shipping Materials; Clean The Appliance - Heat & Glo 350TSI-P-CEM Owner's Manual Installation And Operation

Table of Contents

Advertisement

14

Appliance Setup

A. Remove Fixed Glass Assembly
See Section 9.D.
B. Remove the Shipping Materials
Remove shipping materials from inside or underneath the
firebox.
C. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the firebox or underneath in the control cavity.
D. Accessories
Install approved accessories per instructions included
with accessories. Contact your dealer for a list of ap-
proved accessories.
WARNING! Risk of Fire and Electric Shock! Use ONLY
Hearth & Home Technologies-approved optional acces-
sories with this appliance. Using non-listed accessories
could result in a safety hazard and will void the warranty.
DO NOT MODIFY THIS APPLIANCE
Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17
E. Air Shutter Setting
Air shutter settings should be adjusted by a qualified ser-
vice technician at the time of installation. The air shutter
is set at the factory for minimum vertical vent run. Adjust
air shutter for longer vertical runs. See Figure 14.1.
Loosen the wing nut.
Move the air handle to the left to open the air shutter.
Move the air handle to the right to close the air
shutter.
Tighten the wing nut.
NOTICE: If sooting occur, provide more air by opening
the air shutter.
Figure 14.1 Air Shutter
350TSI-P-CEM
AIR SHUTTER
WING NUT
Natural Gas
Propane
0,6 cm
FULL OPEN
59

Advertisement

Table of Contents
loading