Models:
350TSI-P-CEM
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion could result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT spray aerosols in the vicinity of this
appliance while it is in operation.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This is a room sealed appliance and no other ventilation is
required than what is provided.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures could ignite clothing or other
flammable materials.
• DO NOT place articles on or against this appliance.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
These instructions are only valid if the following country symbol is
on the appliance. If this symbol is not present on the appliance,
it is necessary to refer to the technical instructions which will
provide the necessary information concerning the modification
of the appliance to the conditions of use for the country.
These instructions are valid for the following countries: GB
0086
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 350TSI-P-CEM

  • Page 1 This is a room sealed appliance and no other ventilation is required than what is provided. These instructions are valid for the following countries: GB Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 Copyright 2017 • Printed in U.S.A. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 3: Congratulations

    Consult instructions before installa- tion and use of this appliance. XXXXXXXX Serial: DO NOT REMOVE OR COVER THIS LABEL. XXXX-XXX Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 4: Table Of Contents

    E. Control Module Operation ......50 A. Vent Termination Minimum Clearances ....24 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 5 E. Contact Information ......71   = Contains updated information. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 6: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 7 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 8: Listing And Code Approvals

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 9: High Altitude Installations

    G. Electrical Codes All electrical safety testing has been done following the EN 60335-2-102 standard. Local codes apply. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 10: User Guide

    DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 9.D. MANTEL SECTION 5.D HEARTH CLEAR SPACE SECTION 2.C. GRATE Figure 2.1 General Operating Parts Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 11: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 12: Control Module Operation

    MODULE Figure 2.4 Location of Module Reset Switch (lower right corner of fireplace) SELECTOR SWITCH FLAME HI/LOW STATUS NG/LP GAS-TYPE SWITCH INDICATOR LED SELECTOR SWITCH Figure 2.3 Control Module Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 13: Lighting Instructions (Ipi)

    See installation and operating vice agency or the gas supplier. instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fireplace, please refer to www.fireplaces.com. Final inspection by Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 14: After Fireplace Is Lit

    Wall above appliance feels hot to No action necessary. This appliance ships with a non-combustible material attached. Specifica- the touch. tions of the attached non-combustible material are listed in Section 1.E. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 15: Maintenance And Service

    • Carefully set fixed glass assembly in place on fireplace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 16: Maintenance Tasks-Qualified Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. • Replace fireplace if firebox has been perforated. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 17 • Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sensing rod. Replace pilot as necessary. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 18: Installer Guide

    FIREPLACE MUST BE INSTALLED MANTEL AND AND FLUE PENETRATION COMPLETE MANTEL LEG PRIOR TO FINISH SHEETING (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 19: Design And Installation Considerations

    Non-corrosive leak check solution High temperature caulking material (150 °C minimum continuous exposure rating) 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 20: Framing And Clearances

    27-3/4 See Section D, 350TSI-P-CEM Mantel Projections 102,3 86,4 142,3 41,9 34,3 70,5 154,9 * 61 in. (154,9 cm) when using Tonic or Studio fronts. Figure 5.1 Top-Vent Installation Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 21: Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace could cause overheating and a fire. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 22 (Height) (Width) (Depth) 8-5/8 32 3/4 16-1/4 350TSI-P-CEM 21,9 83,2 41,3 86,4 81,3 91,5 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.2 Clearances to Combustibles Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 23: Mantel And Wall Projections

    (Acceptable on both sides of opening.) HIGH TEMPERATURE (150 ºC MIN.) TOP AND SIDE SEAL JOINT Note: Zero clearance finishing allowed on sides of surround and top of non-combustible board. Figure 5.6 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 24: Termination Locations

    45.0°-49.4° ............1 52 49.4°-53.1° ............1 83 53.1°-56.3° ............2 13 56.3°-59.0° ............2 29 59.0°-60.3° ............2 44 *.91 M minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 25 All gravity air intakes within .91 m of a termination cap must be a minimum requirements. of .30 m below the termination cap. Figure 6.3 Minimum Clearances for Termination Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 26: Vent Information And Diagrams

    • When penetrating a combustible ceiling, a ceiling firestop must be installed. • Horizontal runs of vent do not require vertical rise; Horizontal horizontal runs may be level. Figure 7.1 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 27 = 30 ft. (9,14 m) Maximum Example: SLP pipe 7 ft. (2,13 m) min. vertical = 11 ft. (3,35 m) max. horizontal USE SLP SERIES COMPONENTS ONLY Figure 7.4 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 28 1,22 m 8 ft. 2,44 m 5 ft. 1,52 m 10 ft. 3,05 m = 30 ft. (9,14 m) Maximum = 10 ft. (3,05 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 29 3,66 m = 6 ft. (1,83 m) Maximum *H = 12 ft. (3,66 m) Maximum = 32 ft. (9,75 m) Maximum = 36 ft. (10,97 m) Maximum Figure 7.6 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 30 Failure to keep insulation or other material away from vent pipe could cause over heating and fire. For alternative installations, other than depicted, contact your dealer for further information. Figure 7.7 RESTRICTOR PLATE Figure 7.8 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 31: Vertical

    HORIZONTAL PIPE SUPPORT PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP Flue system termination kits DVP-SERIES SLP SERIES SLP-TRAP2 SLP-TVHW DVP-FBHT Figure 7.9 Flue Components and Terminations Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 32 5 ft. 1,52 m 16 ft. 4,87 m = 36 ft. (10,97 m) Maximum *No specific restrictions on this value EXCEPT cannot exceed 32 ft. (9,75 m) Figure 7.10 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 33 12 ft. 3,66 m 12 ft. 3,66 m = 12 ft. (3,66 m) Maximum = 32 ft. (9,75 m) Maximum USE SLP SERIES COMPONENTS ONLY INSTALLED HORIZONTALLY Figure 7.11 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 34: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one 2,54 cm above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 35: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 36: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 37: Appliance Preparation

    Note: Once the seal cap has been removed, it cannot be reattached. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 38: Installing The Non-Combustible Board

    Figure 9.5 Proper Positioning and Securing of an Appliance • Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 39: Covers Removal For Servicing

    • Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame. Figure 9.7 LATCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 9.6 Fixed Glass Assembly Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 40: Parts Replacement

    • Use non-combustible materials to cover the gap between AIR SHUTTER the sheet rock and the appliance (when applicable to the WING NUT model). Figure 9.8 Air Shutter Natural Gas Propane 350TSI-P-CEM 0,6 cm FULL OPEN Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 41: Installing Vent Pipe (Dvp And Slp Pipe)

    • Only outer pipes are sealed, sealing the inner flue is not required. Figure 10.1 Adding Venting Components • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 42: Secure The Vent Sections

    Figure 10.6 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.7 Align and Disassemble Vent Sections Figure 10.4 Securing Vertical Pipe Sections 120º Figure 10.5 Securing Horizontal Pipe Sections Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 43: Install Support Brackets

    • Check the floor above for any obstructions, such as wir- ing or plumbing runs. • Reposition the fireplace and flue system, if necessary, to accommodate the ceiling joists and/or obstructions. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 44: Heat Shield Requirements For Horizontal Termination

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 45: Install Metal Roof Flashing

    See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 46: Install Vertical Termination Cap

    • Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 10.18). Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 47: Gas Information

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 48: Gas Connection

    Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 49: Electrical Information

    COMPONENTS JUNCTION CORD OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) (MAIN) BLACK BATTERY PACK 6V DC BROWN BATTERY PACK 6V DC GROUND Figure 12.1 IPI Wiring Diagram /RC300CE  Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 50: Blower

    See Figure 12.2 for wire connection de- tail. E. Control Module Operation See Section 2.H for control module operation instructions. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 51 The RC300CE is approved for interior installation and should not be used in exterior applications. • Keep remote control out of reach of children. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 52 Figure 12.5 Remote in Housing Figure 12.3 Temperature Scale 5. Close the housing door. See Figure 12.6. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 53 3 steps, timer based, MED and LOW 3 min. ON, 12 min. OFF FAN CORD LEARN BUTTON Figure 12.9 Programming RC300CE AUX 300 MODULE Figure 12.8 Plug Fan into AUX300CE Module Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 54 Use the SELECT button to select the current Select feature. Menu Menu Use the UP and DOWN arrows to toggle through the menu functions and value selec- Select Select tions in the submenus. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 55 AUX2 settings will be restored to the previous setting. NOTICE: The system will remember the previous FLAME HEIGHT setting and will automatically adjust after 10 seconds. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 56 • Press and hold the MENU and UP arrow buttons simul- taneously for 4 seconds to enable or disable the child lock feature. NOTICE: No functions will be usable until child lock feature is disabled. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 57 At control module, turn off fireplace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 58: Finishing

    Comply with all mini- mum clearances to combustibles as specified in this manu- al. Overlapping materials could ignite and will interfere with proper operation of doors and louvers. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 59: Appliance Setup

    DO NOT MODIFY THIS APPLIANCE AIR SHUTTER WING NUT Figure 14.1 Air Shutter Natural Gas Propane 350TSI-P-CEM 0,6 cm FULL OPEN Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 60: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 5.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 5.7. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 61 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 62: Reference Materials

    GAS LINE ACCESS ELECTRICAL ACCESS Location Centimeters Location Centimeters 83,7 71,4 57,8 61,3 28,9 40,7 40,3 74,1 16,8 17,5 15,3 82,2 98,4 71,2 41,4 22,3 Figure 16.1 Appliance Dimensions Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 63: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 64: Vent Components Diagrams

    (241 mm) 14 in. (356 mm) DRC-RADIUS Cap Shield 5 in. 12 in. (127 mm) (302 mm) 14 in. (352 mm) DVP-BEK2 DVP-HPC Cap Brick Extension Figure 16.2 Vent Components Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 65: Effective

    2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 SLP-FS SLP-WS SLP-HVS Ceiling Firestop Wall Shield Firestop Horizontal Pipe Support Figure 16.3 SLP Series Vent Components Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 66 SL-2DVP Ceiling Firestop Wall Thimble-Black Adapter Black 12 in. (305 mm) 7 in. (178 mm) 15-1/2 in. (394 mm) DVP-FBHT SLP90 SL-2DVP DVP-FBHT Figure 16.4 SLP Series Vent Components Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 67 (146 mm to 213 mm) (213 mm) 3° 87° 15 in. 10-1/2 in. (381 mm) (267 mm) 11 in. (276 mm) SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 16.5 SLP Series Vent Components Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 68: Service Parts

    2033-042 Rocker Switch 2206-299 Lower Door Stop Qty 2 req 2033-125 Wire Assembly 2201-030 Blower 240 Volt Assembly , Optional GFK-240V Additional service parts appear on following page. 4/17 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 69 Jumper Wire, Wall Switch 2179-300 4.15 Shutter Bracket Assembly 2118-121 **Fuse for battery pack can be sourced locally, not a warranty item. Additional service parts appear on following page. Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 70 Top Heat Shield, Interior 2033-307 RC300CE Remote REM300-HNG-CE Conversion Kits Natural to Propane Propane to Natural P2N-350I-CEM Pilot Ori ce N .023 593-528 Pilot Ori ce B .0121 593-527 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...
  • Page 71: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2017 Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17...