Vertical - Heat & Glo 350TSI-P-CEM Owner's Manual Installation And Operation

Table of Contents

Advertisement

MODEL
350TSI-P-CEM
Flue System Approvals And Installations
Approved flue system components are labeled for identi-
fication. NO OTHER FLUEING SYSTEMS OR COMPO-
NENTS MAY BE USED. Detailed installation instructions
are included with each flue termination kit and should be
used in conjunction with this manual. Figure 7.9 shows
flue system components and terminations.
Identifying Flue Components
The flue systems installed on this gas fireplace may include
one, two, or three 90° elbow assemblies. The relationships
of vertical rise to horizontal run in flue configurations using
90° elbows MUST BE strictly adhered to. The rise to run
relationships are shown in the flueing drawings and tables
on the next few pages.
WARNING! Risk of Fire! This gas appliance and flue as-
sembly must flue directly to the outside and must never
be attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance must use a sepa-
rate flue system-common flue systems are prohibited.
SLP SERIES
SLP-TRAP2
Figure 7.9 Flue Components and Terminations

VERTICAL

TERMINATION
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
Flue system termination kits
DVP-SERIES
SLP-TVHW
DVP-FBHT
Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17
FLUE TERMINATION APPROVALS
SLP-TRAP2 HORIZONTAL TERMINATION CAP
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 inches (7,62 cm) from the top of
the pipe.
• Horizontal sections 2-1/2 inches (6,35 cm) at wall shield
firestops.
• Horizontal sections 1 inches (2,54 cm) from sides and
bottom of the pipe.
• Vertical sections 1 inches (2,54 cm) on all sides of pipe.
Failure to keep insulation or other material away from
vent pipe could cause over heating and fire.
For alternative installations, other than depicted, contact
your dealer for further information.
STORM COLLAR
ROOF FLASHING
CEILING
FIRESTOP
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
31