Command Format

3-2-3 WRITE (WT)

One Processing Area
Command Format
Write
Header
ASCII/Hexadecimal code
setting
A: ASCII code, JIS 8 code
H: Hexadecimal code
Processing area
number setting
Response Format
Two Processing Areas
Command Format
W
T
2
Write
A/H
Header
ASCII/Hexadecimal
code setting
Processing area number
setting
Setting value: 0 to 9, A
Note: Setting A is 10.
Response Format
34
Writes data to the Data Carrier. If the Data Carrier is not in the communications
area, an error response (end code: 72 = Data Carrier missing) will be returned.
W
T
A/H
1
X
W
T
Write
Header
Area (1) setting
X
X
X
X
X
X
Start address No.
No. of write bytes
setting
setting
Write
W
T
Header
X
X
X
X
X
Start address No.
setting
0
0
End code
00: Normal completion
(Refer 3-3 End Code List for details.)
Area (2) setting
X
X
X
X
A/H
0
0
End code
00: Normal completion
(Refer 3-3 End Code List for details.)
Section
X
X
Sets the data to be written. The
number of bytes that can be written at
a time is as follows:
– ASCII: 256 characters (256 bytes)
– Hex.:
256 characters (128 bytes)
When hexadecimal code is specified,
2 characters will be included in each
byte of data.
(Refer to page 30, WRITE Command
for details.)
X
X
X
X
X
Specify the number of bytes to be
written in hexadecimal code. The
number of bytes that can be read at a
time is as follows:
– ASCII: 256 bytes (256 characters)
– Hex.:
128 bytes (256 characters)
when hexadecimal code is specified, 2
characters will be included in each byte
of data.
(Refer to page 30, WRITE Command
for details.)
3-2
X

Advertisement