Transmission Specifications
2-5
Host Interface Connector Pin Layout
2-6
Transmission Specifications
2-6-1 Transmission Distances
Pin No.
Description
1
---
2
Receiving data
3
Sending data
4
---
5
Signal ground
6
Data set enable
7
Request sending
8
Clear to send
9
---
Transmission with the currently available V600-series Data Carriers is possible.
Data Carrier
V600-D23P53
V600-D23P54
V600-D23P61
V600-D23P66
V600-D23P66SP
V600-D23P71
V600-D23P72
V600-D8KR04
V600-D8KR12
V600-D8KR13
V600-D2KR16
Note
1. Data Carrier Installation Conditions
V600-D23P53/P54: Embedded in iron.
V600-D23P61:
V600-D23P66/P66SP/P71/P72:
V600-D8KR04/R12/R13:
V600-D2KR16:
(Diagram viewed from the insertion point.)
Abbrevi-
ation
---
---
Host device ← Hand-held Reader Writer
RD
Host device → Hand-held Reader Writer
SD
---
---
SG
---
Host device ← Hand-held Reader Writer
DS
Repeat in the connector section.
RS
CS
---
---
0 to 2.5 mm
0 to 4 mm
0 to 11 mm
0 to 17 mm (see note 2)
0 to 12 mm
0 to 25 mm
0 to 23 mm
0 to 35 mm
0 to 25 mm
0 to 20 mm
0 to 10 mm
Metal (iron) on the back surface of the Data Carrier.
No metal on the back surface of the Data Carrier.
Metal (iron) on the back surface of the Data Carrier.
Data Carrier installed on a bracket (V600-A81) and at-
tached to a metal (aluminium) plate.
Section
Signal direction
Transmission distances
2-6
9