Section 7
Host Communications Specifications

WRITE DATA

This command writes data to the RF Tag in the communications field.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
CmdData/Command Data
Data to write
 Response Area
ErrCode/Response Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
 Execution Example
Writing 1111222233334444 to Four Words Starting from Word Address 1234 Hex in the RF Tag
Command Area
Memory offset
Data name
+1
CmdCode
+2
CmdParam1
+3
CmdParam2
+4
CmdData[0-1]
+5
CmdData[2-3]
+6
CmdData[4-5]
+7
CmdData[6-7]
RFID System
158
User's Manual
(EtherNet/IP
TM
)
Signal/data
Data type
WORD
WORD
WORD
ARRAY[]
OF WORD
Signal/data
Data type
WORD
WORD
WORD
bit15-12 bit11-8
bit7-4
bit3-0
0
0
0
3
1
2
3
4
0
0
0
4
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
Size
16 bits
WRITE DATA (0003 hex)
First word address of the data to write to the RF Tag
16 bits
0000 to FFFF hex
The maximum data size that you can write to an RF Tag
depends on the data size setting (in words).
16 bits
0000 to 0200 hex
* The maximum size that you can specify depends on
the tag data link settings.
1,024 bytes
Data to write to RF Tag
max.
Size
2 bytes
Error code
2 bytes
Error device information
2 bytes
Communications diagnostics result
Response Area
Memory offset
Data name
+1
ErrCode
+2
RespInfo1
+3
RespInfo2
RF Tag Memory
User address
bit15-12 bit11-8
1234
1
Hex
1235
2
Hex
1236
3
Hex
1235
4
Hex
Function
Function
bit15-12 bit11-8
bit7-4
bit3-0
0
0
0
0
0
0
0
0
0
0
0
0
bit7-4
bit3-0
1
1
1
2
2
2
3
3
3
4
4
4

Advertisement