Communications Time

3-3

End Code List

Type
End code
Normal
00
7B
75
76
Host
10
communication
11
12
14
18
Lower
70
communication
71
72
7A
7D
Data Carrier
75
Memory
76
warning
Memory error
93
3-4

Communications Time

48
The end code is expressed with a 2-digit hexadecimal number.
Normal completion
Normal completion, but Data Carrier battery needs to be replaced. (see note 1)
Stops the command auto processing (before communications with the Data Carrier)
Stops the command auto processing (during communications with the Data Carrier)
Vertical parity error
Framing error
Overrun error
Command input error
Frame length MAX error
Data Carrier communication error
Unmatching error
Data Carrier missing error
Address error
Write protect error
For data check or DATA PROCESSING commands
Normal end code (no errors)
For data check or DATA PROCESSING commands
Error end code (error exists)
EEPROM memory error
Note
1. When a "7B" error code is returned, the command was completed normally,
but the battery voltage is low. If the battery voltage is so low that a response
cannot be returned, an error code such as "72" will result.
2. Refer to the 5-1 Error Table for details on each error code.
Communications time differs according to the type of Data Carrier memory
(SRAM or EEPROM). TAT (Turn Around Time) and communications time are
displayed as communication times. TAT represents the total time from when a
command is first sent from the host device to when a response is received. The
communications time represents the time required for communications between
the Hand-held Reader Writer and the Data Carrier – not including communica-
tions with the host device.