Set Information Read (Ul); Command Undefined Response (Ic); Error Response - Omron V600 Operation Manual

Id system, hand-held reader writer
Hide thumbs Also See for V600:
Table of Contents

Advertisement

Command Format
Response Format

3-2-18 SET INFORMATION READ (UL)

Command Format
Response Format
U
L
0
0
T
Header
End code
00: Normal completion
(Refer to 3-4-17 End Code
List for details.)
Communication
speed setting
0: 9,600 bps
1: 2,400 bps
2: 4,800 bps
3: 19,200 bps
Data length setting
0: 7 bits
1: 8 bits

3-2-19 Command Undefined Response (IC)

Response Format

3-2-20 Error Response

46
F
N
Header
Reads the Hand-held Reader Writer setting information.
U
L
Header
R
X
X
X
X
:
Stop bit length setting
0: 2 bits
1: 1 bit
Parity check setting
0: Even number parity
1: Odd number parity
2: None
This is a response the Hand-held Reader Writer will return if it cannot read the
header of a given command.
I
C
Header
If an error occurs during the host communication or lower communication, the
error will be identified by the end code.
0
0
End code
00: Normal completion
(Refer to 3-3 End Code List for details.)
Hand-held Reader Writer system data.
F
N
X
X
:
S
Auto Command Off
0: Yes
1: No
Normal Operating Output
0: Yes
1: No
Section
I
0
0
0
0
0
3-2