Command/Response Format
Two or More Processing
Areas
X
X
Command
Header
ASCII/Hexadecimal
code setting
Number of processing
area setting
Setting value: 0 to 9, A
Note: Setting A is 10.
The number of processing areas can be set to a maximum of 10 areas, and both
ASCII or hexadecimal code can be used within one command.
When multiple area controls are used, the following precautionary items indicate
problems with command descriptions.
• Specify the area in order from the smallest address.
• Areas cannot be specified in duplicate.
A command entry error will occur if the above precautions are not observed.
Area (1) setting
X
Start address
A/H
No. of
bytes written data
Start address No.
No. of bytes of data to be read from the Data Carrier is to be set in
setting
hexadecimal
The number of characters that can be read at one time is 256, so
perform the setting so that the total number of bytes from all areas read
is 256 bytes maximum.
Number of character in Area (1) + ⋅⋅⋅⋅⋅ + area (N) number of characters
≤ 256 characters.
Note
Area (2) setting
Start address
Write ...
A/H
Data to be written to the Data Carrier is to be set.
Set the hexadecimal code setting area to 2
character units.
Count the ASCII code setting as 1 byte per character, and the hex-
adecimal code setting as 1 byte per 2 characters.
Section
No. of
Write
bytes written data
3-1
31