Single Tank Face Piping Installation (Ths 3484, Ths4272, Ths4284 And Ths 4296) - Pentair THS Series Installation And User Manual

Diaphragm valve style face piping
Table of Contents

Advertisement

2.2 Single Tank Face Piping Installation – THS 3484, THS4272, THS4284 and
THS 4296 (6" Flange Connections)
The single tank face piping kit consists of:
(2) 6" 3-way diaphragm valves
(1) Waste pipe extension
(2) Backwash extension
(1) Sightglass assembly (not shown)
(3)
(80) Isoplast bolts
(80) Isoplast nuts
(2) Semi-automatic backwash controller
(See Controller Installation Section)
Verify that all parts listed above were supplied before beginning installation. Replacement
parts can be ordered through your local distributor.
STEP 1: 6" Valve Installation
Place a flange gasket on the influent and
effluent tank flanges. Align the holes in the
gasket with the holes in the flange ring on
the tank. Place valves on the flanges
aligning the holes on the valve flange with
the tank flange ring. Please note the
orientation of the valves. The arrows on
the valve covers should be pointing
toward the tank. Install isoplast bolts and
nuts on the influent and effluent flanges.
Snug the nuts to "hand tight", but do not
fully tighten. This will allow for adjustments
during the remainder of the installation.
Diaphragm Valve Face Piping Kit Installation Manual
5/31/12
6" Flange
gaskets
Pg. 9 of 52
Rev. F