Pentair THS Series Installation And User Manual page 42

Diaphragm valve style face piping
Table of Contents

Advertisement

Connect tubes to each side of the quick connect
tee. Connect one tube to the multiport pressure
gauge and the other to the center fitting on the
multiport valve (see picture).
Drill and tap for ¼" NPT hole on the influent and
effluent pipes from the filter system (see
schematic diagram in Appendix B). Install quick
connect fittings into pipe. Be sure to use pipe
thread sealant tape on the threads. Install 3/8"
OD tube from fittings to rear of the gauge panel
assembly. Connect tubes into correct gauge on
the rear of the panel (see picture).
Assemble the And/Or assembly shown in the
picture. Be sure to leave enough tubing to reach
all of the necessary connections. Connect all
tubes to their appropriate locations as explained
in the picture.
Diaphragm Valve Face Piping Kit Installation Manual
Pg. 41 of 52
5/31/12
Rev. F