STEP 1: Attach Controller/Multiport Enclosures to Piping
Insert notched end of pipe clamps into the
channel of the backwash controller enclosure
support. Attach the backwasher controller
enclosure to the waste extension (see picture).
Slide remaining pipe clamps into the channels of
the enclosure support. Use the nuts and bolts
supplied to tighten the clamps on to the pipe.
STEP 2: Installation of Controller Tubing
Insert a length of 3/8" tube into top fitting on the
regulator (see picture). Connect other end of this
tube to your supply source (water or compressed
air). An extra 3/8" x 1/4" MNPT fitting has been
provided for connection. Please note, the water
source must be able to supply water at a
pressure of 35 psi minimum. Connect the
check valve to the other fitting from the regulator
with a small length of tubing. Make sure that the
arrow on the check valve is pointed away from
the regulator. From the other end of the check
valve, connect a length of tube and attach a
quick connect tee fitting (see picture).
Diaphragm Valve Face Piping Kit Installation Manual