Once system piping and proper valve installation is complete. Including hydraulic lines for valve
activation. Hydro test system*. This must be done prior to adding media, start pump, allow
system to fill with water to (bleed out all air). Run system for several minutes while doing this
inspect for leaks and any unnecessary vibrations that can be reduced by additional support. At this
time you will be checking that the pump is providing the flow and pressures in the desired system.
Once this is done and installer is satisfied the previous criteria has been met, you may proceed in
media installation. Failure to do this may result in damaged parts within the system, which may
result in the warranty being voided.