Contemporary Faceplate Installation Part 2 - Regency P33-5 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

CONTEMPORARY FACEPLATE INSTALLATION PART 2

CONTROL MOUNTING PLATE
INSTALLATION
(FOR P33-4 UNIT WITH FACEPLATE ONLY)
1) Remove top and bottom louvers.
2) Remove ON/OFF switch (for P33-4) from the bottom louver.
3) Attach ON/OFF switch to control mounting plate with one screw as
shown below.
4) If installing the optional fan, see instructions below - otherwise
proceed with the installation of the control mounting plate.
5) Install the control mounting plate over the pin, located at the left base
of the unit. Secure with 1 screw as shown.
INSTALLING THE OPTIONAL FAN
(FOR P33-4 UNIT WITH FACEPLATE ONLY)
120 Volt AC power is needed for the fan switch and blower. The fan can
be hard wired if desired. The receptacle box should be installed on the
left hand side of the unit by a qualifi ed electrician. The neutral (wider) slot
of the polarized receptacle should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal
off under any circumstances.
1) Shut the power off.
2) Turn the fan base on its side (with the base facing towards you) and
then slide the fan in towards the rear of the unit. Turn the fan upright
and slip it over the two mounting studs. Take care not to damage the
insulation on the fan base. Ensure that the fan blades do not rub
against the valve tubing. Diagram 1.
3) Connect fan ground cable to ground lug. Refer to wiring diagram.
®
Regency
P33-5 Zero Clearance Direct Vent Gas Fireplace
Pin
5) Slide the thermodisc/cover assembly into the bracket clip on the un-
derside of the fi rebox. Check that no wire will touch the hot surfaces.
Diagram 2.
Diagram 2
9) Secure the fan wires and power cord by attaching one of the adhesive
backed wire holder clips (Part #910-199) onto the Fireplace base.
Use the second clip to bundle up the wires approximately 4" from
the control box. Ensure that there is no interference with the wires
when the faceplate and trim are installed and that no wire will touch
the hot metal surfaces or sharp edges.
10) Plug the fan power cord into the rear end of the receptacle box to
provide the maximum clearance.
11) Clip the fan control box to the ON/OFF switch (already installed
on the control mounting plate. Secure the fan control box with
one screw as shown below.
12) Install control mounting plate to unit (see step 5 this page).
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life. Do not lubricate them.
Make sure you vacuum the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within your home. Ensure you
maintain these fan motors on a regular basis by vacuuming out the
fan blades and housing using a soft brush nozzle.
INSTALLATION
Diagram 1
43