INSTALLATION
Installation of the DC Sparker
1)
Locate the Piezo Ignitor situated at the
side of valve.
2)
Remove the Piezo Ignitor by unscrewing
the nut at the back of the mounting
bracket.
Ignitor
Wire
Piezo
Ignitor
3)
Disconnect the ignitor wire from the
Piezo Ignitor and connect it to the DC
Sparker.
DC
Sparker
Ignitor
Wire
4)
Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
5)
Locate the ground lug at the receptical
box, left of the unit.
36
6)
Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground
Piezo
wire from
Ignitor
kit
7)
Install the 1/2" bushing to the heat
shield.
8)
Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
Heat Shield
9)
Plug the DC spark generator wires to the
DC Sparker.
10) Connect the ground wire to the DC
Sparker mounting bracket.
11) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
NOTE: The battery in the DC Sparker
Box will need to be replaced annually.
Battery
Compartment
12) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which
is provided in the kit.
13) Find a location which is not too hot and is
easy to reach for changing the battery.
Note: It should be kept away from the
chain.
14) Tie up the loose wire with the wire clip.
®
Regency
P33-5 Zero Clearance Direct Vent Gas Fireplace
Chain