THERMOPILE/
THERMOCOUPLE
1) Open the bottom louvers.
2) Loosen the thermocouple or thermopile with a
7/16" wrench.
3) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Disconnect
thermopile by loosening 2 screws marked TP
on the valve.
4) Drop the thermocouple or thermopile down from
the bracket and pull it out of the unit.
5) Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use 5/8"
fl at glass gasket for the Bay Front (Part # 936-243)
and a tadpole glass gasket for the Flush Front (Part
# 936-155).

DOOR GLASS

®
Your Regency
fi replace is supplied with high
temperature, 5 mm Neoceram ceramic glass that will
withstand the highest heat that your unit will produce.
If your glass requires cleaning, we recommend
using an approved glass cleaner available at all
authorized dealers. Do not use abrasive materials.
Do not clean the glass when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
®
Regency
dealer only, and follow our step-by-step
instructions for replacement.
WARNING: Do not operate the
ap pliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.
Caution: Wear gloves when removing
damaged or broken glass.
Flush Glass Replacement
Remove the fl ush door front. Remove the 4 glass
clips from each corner. Slide in the new replacement
glass. Push the 4 glass clips back onto the frame.
The glass must have gasketing around it.