Service menu
6.4.2
DHW alternating operation
In DHW alternating operation, DHW and heating have equal priority and
alternate based on time. A heat requirement from the heating system is
not taken into account while DHW heating is active, and vice
versa.
Menu:
DHW
alternating operation
~
BOSCH
If DHW alternating operation is not active, DHW has priority and
interrupts the heat requirement of the heating system, if
necessary.
No
l
in the event that both DHW and heating are required atthe same time, the system will alternate between DHW
I
heating and heating mode based on the times set under "DHW priority for" and "Prioritise heating
for".
DHW heating has the higher priority and interrupts heating
mode,
if
necessary.
DHW priority for
o
...
30
...
120 min
Prioritise heating for
5
...
20
...
120 min
Table 32 Operating mode for DHW heating
6.5
Swimming pool
settings
The switching time forthe swimming pool divertervalve and the auxiliary
heater switch-on delay for heating the pool can be set in this
menu.
Menu
item
Adjustment range
Pool module available?
Yes
Duration of DHW heating for DHW
altern.
oper.
on.
Duration of heating mode for DHW
altern.
oper.
on.
description
A pool module is installed in the
system.
No
I
The swimming pool heating system is controlled without a pool
module.
Pool mixing valve
10
...
60005
Add.
heat. switch·on delay
I
60
...
1200 K'min
Logic external connection
Open contact
tciosed contact
- -
Table 33
6.6
Solar system settings
Solar
thermal sys installed
Current solar configuration
._---
Solar
parameters
I
Start solar thermal system
!
No
6720 811 136-504.10
Fig. 15 Solar settings menu
If a solar system is integrated into the heating system via module,
corresponding menus and menu items are
available.
An extension of the
menus by the solar system is described in the operating instructions of
the used module.
In the
Solar
settings
menu
with all solar systems
the sub-menus listed
in
Tab.
34 are
available.
&
WARNING: Risk of scalding!
I
~
If DHW temperatures above 60 °C are set or thermal
disinfection is switched on, a mixing device must be
installed.
&
NOTICE: System damage
!
~
Fill and ventthe solar system priorto
commissioning.
I
'
If the area of the installed solar collectors is incorrectly
set. the solar yield displayed in the info menu is wrong as
well.
Duration of the switchover for the swimming pool mixing
valve.
Auxiliary heater switch·on delay for heating the swimming pool.
Open contact at the external connection is interpreted as
"On".
~~~
Closed contact at the external connection is interpreted as
"On".
Menu item
Purpose of the menu
Solar thermal sys installed If Yes is set here, the other settings are
displayed.
Change solar configuration Graphical configuration of the solar system
Current solar configuration Graphical representation ofthe configured
_,..--_ _ _ _ _ _ -'-'
s
. ,..
o
~
la
~
r sy
~ s_::_ te~
m
-:---:----:----_i
Solar parameters
Settings for the installed solar system
Start solar thermal system Once all the required parameters have
been set. the solar system can be started
up.
Table
34
General settings for the solar system
6.7
Hybrid system settings
The energy/price ratio can be set in the
Hybrid system
menu. Further
information is available in the instructions supplied with the hybrid
system
components.
6.8
Anti-seizing function settings
The
Anti-seizing protection
menu can be used to set when the anti-
seizing function is
activated.
The start time can be adjusted in i-hour
increments between 00:00 and
23:00.
6.9
Commissioning complete
This menu is used to confirm and save all settings done in the service
menu, when the commissioning is complete. After first commissioning,
the settings should be saved whenever a change is
done.
6.10
Diagnosis menu
I
Function test
Monitored values
Fault displays
System information
Maintenance
>
.
>
!
!
6720 811 136-505.10
Fig.
16
Diagnosis menu
26