Thermal Disinfection - Bosch HPC 400 Installation Instructions For Contractors

User interface ems 2
Table of Contents

Advertisement

@)
BOSCH
Service menu
.
.
-
.
As hot water system
I
Activate the same time program for circulation as for DHW
heating.
Further information and settings of the
I
customised time program
(~
user interface operating instructions)
.
Own time program
Activate customised time program for
circulation.
Further information and settings of the customised time
I
I
program
(~
user interface operating instructions)
.
Start frequency DHW
circ.
l )
I
lf the DHW circulation pump is active via the time program for the DHW circulation pump or if it is permanently
I
switched on (DHW circulation pump operating
mode:
On)
.
this affects the settings for the DHW circulation
11 x 3 minutes/h
...
I
pump
operation.
I
The DHW circulation pump goes into operation once
...
6 times per hour for 3
minutes.
The default setting
6 x 3 minutes/h
,
depends on the installed heat
source.
Permanently
The DHW circulation pump is in permanent
operation.
Thermal disinfection
I
Yes
Thermal disinfection always starts automatically at the same time
(e.g.
on Mondays at 2:00.
~
Chapter 6.4.1
.
----t
page 25)
-
- -
- -
-
-
- - - -
- -
No
The thermal disinfection is not started
automatically.
Therm.
disinfection day
I
Monday
...
Tuesday
...
The day on which thermal disinfection is
performed.
Sunday
Daily
~
Thermal disinfection is performed
daily.
- - - c - - -
-
- -
----
- - -
- - -
- -
-
- -
Therm. disinfection time
00:00 ...
02:00
Time of day for the start of thermal disinfection atthe set day.
-1
...
23:45
-:-:-
- -
- -
-
- - - - -
- - - - - - - -
Max.
period
60 min
...
240 min
Maximum duration of thermal
disinfection.
The adjustment range depends on the installed heat
pump.
Extra DHW temperature
50
...
70 °C
Switch-off temperature for extra
DHW.
i
Daily heat-up
Yes
The entireDHW volume is automatically heated up daily at the same time to 60
°C.
- -
I-
-
- -
- -
- - - - -
INo
No daily
heat-up.
Daily heat-up time
1
00:00
...
02:00
Time for the start of the daily heat-up to 60 °C.
...
23:45
DHW alternating operation
I
lf a simultaneous heat requirements from the heating system and the DHW system are present. the heat pump
I
can alternatingly supply the heating system and DHW
(
~
Chapter
6.4.2.
page 26)
.
HC pump on at DHW running
Yes
-+
All heating pumps are running when DHW heating is
active.
INO
-
- -
- -
- - -
---
The heating pumps do not run when DHW heating is
active.
Table
31
Settings in the DHW menu
1) Not available if Sweden or Finland is set as the
country.
the DHW circulation pump is always on if installed
6.4.1
Thermal disinfection
WARNING: Risk of
scalding!
During thermal
disinfection.
the domestic hot water is
heated to above 60
a
c.
~
Only carry out thermal disinfection outside normal
hours of use.
~
Inform all parties concerned and make sure that at
mixing device is
installed.
Perform thermal disinfection to kill off pathogens (e.g.legionella) on a
regular
basis.
For larger DHW systems. there may be legal requirements
(-7 regulation on drinking water) for thermal
disinfection.
Observe the
instructions in the technical documentation of the heat
source.
Yes:
- The entire DHW volume is heated to the set temperature
once.
- The thermal disinfection starts automatically at the set time
according to the time set in the user
interface.
- It is possible to cancel and to manually start the thermal
disinfection.
No:
The thermal disinfection is not started
automatically.
It is
possible to manually start and cancel thermal
disinfection.
- - - j
HPC 400
~
6 720821
r
72 12011 O?)
25