Eliminate fault
:::: ".i:.
~
Test procedure/Cause
Corrective measure
~
"8
~:::
Cause orfault description
A51 6022 Bottom temperature sensor for
Check
configuration.
The selected setting reqUires a cylinder
Change configuration
cylinder 1 defective
sensor at the bottom
I
Standby mode active
I
Check connecting lead between solar module and collector
I
Establish a connection properly
temperature sensor
,
Check the electrical connection of the connecting lead at the
Ilf a screw or plug is
loose.
rectify the contact problem
solar module
Check bottom cylinder temperature sensor according to table
If values do not match. replace the sensor
- -
- -
- - -
~~
Check the voltage at the connecting terminals of the cylinder
If the sensor values matched. but the voltage values
I
temperature sensor at the solar module according to table
do not
match.
replace the module
j
I
A61
I--
r-------
-
~
- - -
- -
- - -
1081 Two master user interfaces in the
Check parameterisation at the installation level
Remove all other user interfaces from the
system.
A62 1082
system.
I
(In the BUS
system.
further user interfaces are configured as the
A63 1083
controller in addition to the HPC400)
A64 1084
H01 5203
Alarm Outside temperature
I
Check the connecting lead between the controller and outside
If there is no continuity. rectify the fault
I
sensor Tl fault
temperature sensor for continuity
Check the electrical connection of the connecting lead in the
Clean corroded connecting terminals in the outside
I
outside temperature sensor or on the plug in the controller
I
sensor housing.
I
Check outside temperature sensor according to table
If values do not
match.
replace the sensor
Check the voltage at the connecting terminals of the outside
If the sensor values matched. but the voltage values
temperature sensor in the controller according to table
do not
match.
replace the controller
H01 5239
Alarm DHW sensor T3 fault
I
No hot water system installed
Deactivate hot water system in the service menu
If the DHW function is not
I
Check connecting lead between controller and hot water
I
If there is a defect. replace the sensor
needed.
deactivate it on the user temperature sensor
I
interface
Check the electrical connection of the connecting lead in the
If a screw or plug is
loose.
rectify the contact problem
~~roller
Check the hot water temperature sensor according to table
If values do not match. replace the sensor
-
I
Check the voltage at the connecting terminals of the hot water
If the sensor values matched. but the voltage values
I
temperature sensor in the controller according to table
do not match. replace the controller
H01 5284
1
Warning Last thermal
i
Check if water is possibly being drawn from the DHW cylinder If water is being drawn constantly. take action to stop
1
A41 4051
disinfection failed
constantly due to a leak or taps being open
this
Check the position of the hot water temperature
sensor;
it may
Position the hot water temperature sensor.correctly
I
be attached incorrectly or suspended in the air
I
I
Check whether the heating coil in the cylinder has been vented
Vent if necessary
completely
Check the connection pipes between the boiler and cylinder.
Rectify any faults in the pipework
I
and with the aid of the installation
instructions.
ensure that they
are connected properly
Using the technical documentation. check whether the installed
I
Replace the pump if there are deviations
cylinder primary pump is providing the required output
~cessive
losses in DHW circulation line
Check DHW circulation line
~
- - -
I
Check the hot water temperature sensor according to table
Replace the sensor if there are deviations from the
table values
Table 38 Fault displays