Setting the Heating curve for underfloor heating system
TCxl°C
60
, - , - , , - . - , , - , - , , - . - ,
50
~~~~/~~~=+~~
40
~~~~~~~-b-~~
30
~~=+-~~~~~~\~
Service menu
T /oC
20L-~---~-~---~
1
+20
+10
0
-10
-20
6720
815 238-13.10
Left: gradient via design temperature TAL and minimum outside temperature Tl,min
Right: parallel displacement via room-temperature offset or via required room temperature
T
1
Outside temperature
TCx/OC
90
80
70
60
50
40
30
20
T
/oC
1
+20
+10
0
-10
-20
Fig_
9
Setting the Heating curve for radiators/convectors
TCxFlow temperature of heating circuit x (identical to system flow tem-
perature TO if only one heating circuit
is
installed)
[1]
Setting: TAL
= 45
D
C, T
l.min
= -10
D
C (base curve). limit atTCx
max
=
48
D
C
[2]
Setting: TAL
= 40
D
C, T
l.min
= -10
DC
[3]
Setting: TAL
=
35
DC,
T
1,min
= -
20
DC
[ 4]
Parallel displacement ofthe base curve [1] by changi ng the room
temperature offset +3 or by increasing the desired room
temperature, limit at TCx
max =
48
DC
[51
Parallel displacement of the base curve [1] by changing the room
temperature offset
-3
or by reducing the desired room
temperature
TCxl°C
90
80
70
60
50
40
30
20
+20
+10
o
-10
6720
815
238-15.10
Left:
gradient above design temperature TAL and minimum outside temperature Tl,min
Right: parallel displacement via room temperature offset or required room temperature
T
1
Outside temperature
TCxFlow temperature of heating circuit x (identical to system flow tem-
perature TO
if
only one heating circuit
is
installed)
[1]
Setting: TAL
= 75
D
C, T
1,min
= -10
D
C (basecurve).limitatTCx
max
=
75
D
C
[2]
Setting:
TAL
= 80
DC,
T
l.min
= -10
D
C, limit atTCx
max
= 80
D
C
[3]
Setting: TAL
= 70
D C,T
1 min
=-20
D
C
Simple heating curve
The simple heating curve (outsjde temperature compensated control
with base point) is a simplified representation of the heating curve_ This
straight heating curve is described by two
points:
the base point (the
heating curve starting point) and the end point
Underfloor
Radiator
heating system,
convector
Minimum outside temperature T
i,min
-
10"C
-10 °C
I
[4]
Parallel displacement
of
the base curve [1] by changing the room
temperature offset +3 or by increasing the desired room
temperature, limit at TCx
max
=
75
DC
[5]
Parallel displacement ofthe base curve [1] by changing the room
temperature offset
-3
or by reducing the desired room
temperature, limit at TCx
max
=
75
DC
Base point
End point
I
25 °C
25°C
J
-
--
-
-
45 "C
60°C
Maximum flow
temperature
TCx
max
48 °C
75 °C
Room temperature offset
O,OK
O ,OK
-
Table
29
Simple heating curve basic settings