DURKOPP ADLER 911-210-3020-10 Operating Instructions Manual page 75

Table of Contents

Advertisement

Programming
Operating Instructions 911-210-10 - 00.0 - 06/2020
MP2 - Limit values
Symbol
Meaning
Max. speed
(min. = 500 .. max. = 2700; Def. 2700 rpm)
All sewing programs are limited to this maximum speed
Max. run-empty speed
(min. = 10 .. max. = 100; Def. 100 %)
Limits all clamp movements between the seams to this value
Feed starting angle
(min. = 30 .. max. = 350; Def. 210 degrees)
The clamp motion during the stitch starts at this angle of needle motion
Feed phase
(min. = 30 .. max. 100; Def. 80 %)
This parameter defines how the clamp is to be moved during the stitch.
(A value of 100 % means that the desired clamp motion is distributed over
the entire stitch.)
Reversal position
(min. = 0 .. max. 359; Def. 0 degrees)
The needle is reversed at this angle in order to increase the clearance to
the clamp.
Edit times and routes
This function is only for Dürkopp Adler Service personnel
MP3 - Needle thread monitor
Symbol
Meaning
Needle thread monitor mode
The following options are available:
• Threading position: After detection of a thread breaking, the thread is
cut, and the clamp then moves to the threading position
• Thread cutting (Def.): After detection of a thread breaking, the thread is
cut, and the clamp then moves to the contour position according to the
defined reversing path
• Pausing: After detection of a thread breaking, seam motion is stopped
• Not activated: The needle thread monitor is ignored
Reversing path after thread breaking
(min. = 0 .. max. 20; Def. 5 stitches)
Number of stitches to be taken into account when reversing after a thread
breaking