Connecting To An Asynchronous Terminal Or Pc; Verifying That Self-Test Passed - Paradyne framesaver 9623 Installation Instructions Manual

Table of Contents

Advertisement

Connecting to an Asynchronous Terminal or PC

A VT100-compatible asynchronous terminal or a PC providing VT100 terminal
emulation must be used to set up access to and management of the unit.
Procedure
1. Configure the terminal or PC so it is compatible with the FrameSaver unit:
— Baud Rate set to 19.2 kbps.
— Character length set to 8 data bits.
— Parity set to none.
— Stop bit set to 1.
— Flow Control set to None.
2. Insert the DB25 end of the EIA-232 cable into the FrameSaver unit's COM port.
COM
Port
3. Insert the other end of the cable into the terminal or PC.
4. Tighten the screws on each side of the connector to secure the cable.
5. Press Enter on the keyboard to display the Main Menu.
If the Main Menu does not appear, recheck the terminal or PC settings (see
or press the Enter key. Refer to Troubleshooting in the FrameSaver SLV Operations
Guide for other possible explanations.

Verifying that Self-Test Passed

To verify that the unit passed its self-test, go to the System and Test Status screen.
Main Menu
The results of the self-test appear directly under the screen title.
If any failure messages appear, reset the unit by disconnecting, then reconnecting the
power cord. The unit will perform the self-test again. If the failure reappears, call your
service representative for assistance.
ETHERNET
COM
POWER
Status
System and Test Status