Charge And Link Mode; Linked Modes - Honeywell Xenon Series User Manual

Area-imaging scanners
Table of Contents

Advertisement

In order to program the base for Charge Only Mode, you must link a scanner to it.
Once the scanner is linked to the base, scan the Charge Only Mode bar code. Any
subsequent scanners placed in that base will charge without linking to it. The
scanner used to program the base remains linked to the base. To unlink this scan-
ner, scan
Note: When in Charge Only Mode, the scanner periodically wakes up and beeps. See "Power
Up Beeper" on page 5-113 to change this setting.

Charge and Link Mode

If you want to charge a scanner and link to the base, use Charge and Link Mode. If
the base is programmed for Charge Only Mode, you must link a scanner to it first in
order to program it for Charge and Link Mode. Scan the linking bar code on the
base to link the scanner, then scan Charge and Link Mode. Default = Charge and
Link Mode.

Linked Modes

Locked Link Mode and Open Link Mode are the link modes that accommodate dif-
ferent applications. Scan the appropriate bar codes included in the Open Link and
Locked Link Mode explanations that follow to switch from one mode to another.
Default = Open Link Mode.
Locked Link Mode - Single Scanner
If you link a scanner to a base or an Access Point using the Locked Link Mode,
other scanners are blocked from being linked if they are inadvertently placed into
the base, or if the Access Point linking bar code is scanned. If you do place a differ-
ent scanner into a base, it will charge the scanner, but the scanner will not be
linked.
To use a different scanner, you need to unlink the original scanner by scanning the
Unlink Scanner bar code. (See
Xenon/Granit User Guide
Unlink Scanner
on page 58.
Charge Only Mode
* Charge and Link Mode
Locked Link Mode
(Single Scanner)
Scanner
Modes, page 56.)
57

Advertisement

Table of Contents
loading

Table of Contents