Fixing Configuration Errors - Extreme Networks BlackDiamond 6800 Installation And User Manual

Asynchronous transfer mode (atm) module
Hide thumbs Also See for BlackDiamond 6800:
Table of Contents

Advertisement

Table 2-1: ATM Module and Port LEDs (continued)
LED
Port x

Fixing Configuration Errors

If the STATUS LED on the ATM module turns amber and blinks, use the
command to display the configured slot type. The output from this command also
displays information about the module state, including the CARD MISMATCH
message. This message indicates that the slot was previously configured for a module
type different than the one you just installed.
Use one of the following commands to reset the slot configuration:
clear slot <slot>
unconfig slot <slot>
config slot <slot> module [a3c | f32t | f32f | f48t | g4x | g6x | g8x |
g12x | p3c | p12c | wdm]
The first two commands listed above clear the slot of a previously assigned
module type. The third command replaces the existing module type configuration
with a new module type configuration.
Asynchronous Transfer Mode (ATM) Module Installation and User Guide
Color
Indicates
Green
Link up
Green blinking
Link disabled
Amber blinking,
Activity on link
returning to green
Amber blinking
Link down; SONET link problem
No received signal
Off
Troubleshooting
Corrective action
(No action required.)
See "Fixing Link Down
Problems" on page 2-16.
(No action required.)
See "Fixing Link Down
Problems" on page 2-16.
See "Fixing Link Down
Problems" on page 2-16.
show slot