Identifying Problem Categories - Extreme Networks BlackDiamond 6800 Installation And User Manual

Asynchronous transfer mode (atm) module
Hide thumbs Also See for BlackDiamond 6800:
Table of Contents

Advertisement

Installing or Replacing an ATM Module

Identifying Problem Categories

Table 2-1
lists the color states of ATM module and port LEDs and describes their
associated meanings. The STATUS and DIAG LEDs apply to the module as a whole; the
port status LED for each port provides status information about that port.
Table 2-1: ATM Module and Port LEDs
LED
Color
STATUS
Green blinking
Amber blinking
Off
DIAG
Amber blinking
Amber
Off
2-12
Indicates
Normal operation
Configuration error (configured
slot type is different than
inserted module type)
Version error (ExtremeWare
version does not recognize
inserted module)
Version error (the ATM module
image version is not compatible
with the MSM image version)
Hardware error (module failed
diagnostics)
Network processor or GPP
down (as detected by network
processor heartbeat protocol)
No power
Diagnostics in progress
Diagnostics failed
No diagnostics in progress
Asynchronous Transfer Mode (ATM) Module Installation and User Guide
Corrective action
(No action required.)
See "Fixing Configuration
Errors" on page 2-13.
See "Upgrading the Switch
Software Image" on
page 2-14.
See "Upgrading the ATM
Module Software Image"
on page 2-14.
See "Identifying Conditions
for Replacing an I/O
Module" on page 2-16.
Reboot slot. If condition
persists, run diagnostics.
See "Fixing Power-Related
Problems" on page 2-15.
(No action required.) Use
the show diagnostics
{<slot>} command to see
test status.
See "Identifying Conditions
for Replacing an I/O
Module" on page 2-16.
(No action required.)

Advertisement

Table of Contents
loading

Table of Contents