6.2.2 Error Messages and Display Problems
PROBLEM
Controller displays
low temp or LO.
Controller displays
Hot hi-1.
Controller displays Hi
temp.
CM III.5 displays HI .
Controller displays
RECOVERY
FAULT/ YES and
alarm sounds.
Controller display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Controller displays
High limit
failure
disconnect
power or HELP.
Controller displays
TEMP PROBE
FAILURE or PROB.
Controller displays
SERVICE
REQUIRED followed
by an error message.
PROBABLE CAUSES
Frypot temperature has dropped
more than 30°F (17°C) lower than
setpoint in idle mode or 45°F
(25°C) in cook mode.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
Frypot temperature is more than
40 ºF (4ºC).
Fryer is more than 21ºF (12ºC)
above setpoint.
Recovery time exceeded maximum
time limit.
Incorrect display option
programmed.
A. Open drain valve
B. Failed high limit
Problem with the temperature
measuring circuitry including the
probe or damaged controller
wiring harness or connector.
An error has occurred which
requires a service technician.
CORRECTIVE ACTION
This display is normal for a short while if a
large batch of frozen product is added to the
frypot or if the fryer is not heating properly. If
the issue persists call your FAS for assistance.
Shut the fryer down immediately and call your
FAS for assistance.
Press the power button to turn off fryer and let
cool before returning power to fryer. If issue
continues call your FAS for assistance.
This display is normal if the fryer setpoint has
been changed to a lower temperature. The
display should revert to the normal four
dashes when the frypot temperature cools to
the setpoint. If the setpoint has not been
changed, this indicates a problem with the
temperature control circuitry. Turn the fryer
off and call FAS.
Clear error and silence the alarm by pressing the
 (YES) button. Maximum recovery time is
2:25. If the error continues call your FAS for
assistance.
Fryers using the 3000 controller can toggle
between F° to C° by pressing the  button until
Product setup is displayed. Press  to scroll to
Tech Mode and press . Enter 1658. Press the
scan button. The controller displays OFF.
Turn the controller on to check temperature. If
the desired scale is not displayed, repeat. Fryers
using the CM3.5 should refer to the separate
Fryer Controllers User's Manual.
A. Close the drain valve.
B. Shut the fryer down immediately and call
your FAS for assistance.
Shut the fryer down and call your FAS for
assistance.
Press the  (YES) button if the issue is fixed or
press the  (NO) button to continue cooking
and call your FAS for assistance. In some cases,
cooking may not be available.