Frymaster FPGL30 Installation, Operation And Maintenance Manual page 33

Oil conserving fryer
Table of Contents

Advertisement

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will
rush out creating the potential for severe burns.
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage
to the ball inside will result in leaks and will void the Frymaster warranty.
4. After the oil has drained from the frypot
and when prompted, rotate the filter
handle towards the "I" to start the pump
and begin the filtering process. There
may be a slight delay before the pump
activates (see Figure 8).
5. The filter pump draws the oil through the filter medium and circulates it back up to and through
the frypot during a filter.
6. After the oil is filtered, close the drain valve when prompted and allow the fryer to refill. Let the
filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.
7. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not
operate.)
8. Turn the filter off when prompted.
The computer displays OFF when finished.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
DANGER
DANGER
WARNING
Filter Pump Reset Switch
4-4
Rotate filter handle to
activate pump.
(Position of handle
may differ from photo.)
Figure 8