TABLE 13
LGH/LCH480H - R410A - CAV
Circuit 1
Circuit 2
Outdoor
Coil En­
DIs
Suc
Dis
tering Air
+10
+5
+10
Temp
psig
psig
psig
65_F*
231
127
296
75_F
292
134
336
85_F
322
135
380
95_F
386
137
434
105_F
436
143
487
115_F
500
146
546
TABLE 14
LGH/LCH480H - R410A - VFD
Circuit 1
Circuit 2
Outdoor
Coil En­
DIs
Suc
Dis
tering Air
+10
+5
+10
Temp
psig
psig
psig
65_F*
250
121
283
75_F
301
124
324
85_F
331
136
371
95_F
390
130
420
105_F
428
131
477
115_F
479
134
537
TABLE 15
LGH/LCH540S - R410A - CAV
Circuit 1
Circuit 2
Outdoor
Coil En­
DIs
Suc
Dis
tering Air
+10
+5
+10
Temp
psig
psig
psig
65_F*
291
122
308
75_F
326
126
350
85_F
375
129
400
95_F
412
132
440
105_F
464
134
494
115_F
506
136
539
TABLE 16
LGH/LCH540S - R410A - VFD
Circuit 1
Circuit 2
Outdoor
Coil En­
DIs
Suc
Dis
tering Air
+10
+5
+10
Temp
psig
psig
psig
65_F*
285
119
324
75_F
329
121
368
85_F
391
125
418
95_F
454
127
476
105_F
497
130
525
115_F
554
133
580
TABLE 17
LGH/LCH600S - R410A - CAV
Circuit 1
Circuit 2
Outdoor
Coil En­
DIs
Suc
Dis
tering Air
+10
+5
+10
Temp
psig
psig
psig
65_F*
258
123
336
75_F
316
125
375
85_F
376
129
422
95_F
425
132
466
105_F
478
134
533
115_F
535
137
596
507232-02
9/2015
Circuit 3
Circuit 4
Suc
DIs
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
133
264
130
369
135
301
132
293
137
344
135
343
139
390
136
373
142
442
139
433
144
496
141
487
Circuit 3
Circuit 4
Suc
DIs
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
124
267
140
273
126
305
142
306
127
349
143
355
131
398
146
389
132
456
147
459
134
516
149
522
Circuit 3
Circuit 4
Suc
DIs
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
127
300
125
295
129
335
128
330
133
385
133
380
136
423
134
423
138
475
136
469
140
520
138
506
Circuit 3
Circuit 4
Suc
DIs
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
124
320
138
310
125
355
139
350
128
400
142
400
129
460
144
450
133
515
145
500
136
570
147
555
Circuit 3
Circuit 4
Suc
DIs
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
126
291
125
298
127
324
126
316
130
369
129
362
132
414
131
395
134
469
133
444
138
530
136
509
Circuit 1
Outdoor
Coil En­
Suc
DIs
tering Air
+5
+10
psig
Temp
psig
130
65_F*
251
131
75_F
304
132
85_F
343
133
95_F
398
137
105_F
445
139
115_F
490
E-Charge Verification - Approach Method - AHRI
Suc
TESTING
+5
psig
1-Using
the
140
temperature to outdoor ambient temperature.
142
Approach Temperature = Liquid temperature (at
144
condenser outlet) minus ambient temperature.
147
148
2-Approach temperature should match values in table 19.
150
An approach temperature greater than value shown
indicates an undercharge. An approach temperature
less than value shown indicates an overcharge.
Suc
3-The approach method is not valid for grossly over or
+5
undercharged systems. Use tables 7 through 18 as a
psig
125
guide for typical operating pressures.
127
132
134
137
420S, 480S
138
420H , 480H, 600S
540S
Suc
420S, 540S
+5
psig
420H, 480H,
139
480S
140
600S
142
144
147
149
Suc
+5
psig
124
125
127
129
131
134
Page 33
TABLE 18
LGH/LCH600S - R410A - VFD
Circuit 2
Circuit 3
Suc
Dis
Suc
DIs
+5
+10
+5
+10
psig
psig
psig
psig
109
300
111
297
111
342
113
338
114
388
115
382
117
433
117
433
119
489
119
485
122
545
121
537
same
thermometer,
TABLE 19
APPROACH TEMPERATURES
CONSTANT AIR VOLUME
Unit
Approach Temperature
8°F + 1 (4.4 + 0.5)
6°F + 1 (3.3 + 0.5)
7°F + 1 (3.9 + 0.5)
VARIABLE AIR VOLUME
8°F + 1 (4.4 + 0.5)
6°F + 1 (3.3 + 0.5)
9°F + 1 (5.0 + 0.5)
7°F + 1 (3.9 + 0.5)
Circuit 4
Suc
DIs
Suc
+5
+10
+5
psig
psig
psig
135
295
135
136
335
137
139
384
140
141
424
142
142
477
144
145
521
146