BLOWER DATA
POWER EXHAUST FANS
1
STANDARD STATIC (
TWO FAN OPERATION)
Return Duct
Negative Static Pressure
Inches Water Gauge
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
For one fan operation, use half of the air volume value.
1
OUTDOOR AIR PERCENTAGE VS. FRESH AIR DAMPER ANGLE - Less ERW
Opening Angle
NOTE - Outdoor air percentage will vary when a variable frequency drive (VFD) drive is used on the supply air blower.
OUTDOOR AIR PERCENTAGE VS. FRESH AIR DAMPER ANGLE - With ERW
1
ERW
Static
Pressure
in. w.g. 1.2
10°
- - -
20°
9%
30°
23% 18% 13%
Fresh Air
40°
38% 32% 27% 22% 17% 11% 43% 38% 32% 27% 22% 17% 48% 43% 38% 32% 27% 22%
Damper
Opening
50°
52% 46% 41% 36% 31% 25% 57% 52% 46% 41% 36% 31% 62% 57% 52% 46% 41% 36%
Angle
60°
66% 61% 55% 50% 45% 39% 71% 66% 61% 55% 50% 45% 77% 71% 66% 61% 55% 50%
70°
81% 75% 70% 64% 59% 54% 86% 81% 75% 70% 64% 59% 91% 86% 81% 75% 70% 64%
80°
95% 89% 84% 78% 73% 68% 100% 95% 89% 84% 78% 73% 100% 100% 95% 89% 84% 78%
1
ERW
Static
Pressure
in. w.g.
1.2
10°
- - -
20°
25%
30°
39%
Fresh Air
40°
54%
Damper
Opening
50°
68%
Angle
60°
84%
70°
97%
80°
100%
NOTE - Outdoor air percentage will vary when a variable frequency drive (VFD) drive is used on the supply air blower.
See page 37 for Energy Recovery Wheel Specifications.
1
Air Volume
cfm
12,100
11,600
11,150
10,600
10,100
9500
8900
8200
7400
6500
Fresh Air
Damper
0.2
10°
5%
20°
19%
30°
34%
40°
48%
50°
62%
60°
77%
70°
91%
80°
100%
Percentage of Outdoor Air Available at Various Return Duct Static Pressures
0 Return Duct Static
1.0
0.8
0.6
0.4
0.2
- - -
- - -
- - -
- - -
- - -
4%
- - -
- - -
- - -
- - - 14%
8%
2%
- - - 28% 23% 18% 13%
Percentage of Outdoor Air Available at Various Return Duct Static Pressures
0.6 Return Duct Static
1.0
0.8
0.6
- - -
- - -
- - -
19%
14%
9%
34%
28%
23%
48%
43%
38%
62%
57%
52%
77%
71%
66%
91%
86%
81%
100%
100%
95%
Return Duct
Negative Static Pressure
Inches Water Gauge
Percentage of Outdoor Air Available at Various
Return Duct Static Pressures - in. w.g.
0.4
11%
25%
39%
53%
68%
82%
96%
100%
0.2 Return Duct Static
1.2
1.0
0.8
0.6
- - -
- - -
- - -
- - -
9%
4%
- - -
0.4
0.2
1.2
- - -
- - -
- - -
4%
- - -
30%
18%
13%
44%
32%
27%
59%
46%
41%
73%
61%
55%
87%
75%
70%
100%
89%
84%
100%
Page 25
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.6
0.8
16%
21%
30%
36%
44%
50%
59%
64%
73%
79%
87%
93%
100%
100%
100%
100%
0.4 Return Duct Static
0.4
0.2
1.2
1.0
- - -
- - -
- - -
- - -
- - -
- - - 19% 14%
8%
2%
34% 28% 23% 18% 13%
0.8 Return Duct Static
1.0
0.8
- - -
- - -
25%
19%
14%
39%
34%
28%
54%
48%
43%
68%
62%
57%
84%
77%
71%
97%
91%
86%
100%
100%
100%
Air Volume
cfm
5700
5000
4300
3800
3400
3000
2500
2300
2000
0.8
0.6
0.4
0.2
- - -
- - -
- - -
- - -
9%
4%
- - -
- - -
8%
0.6
0.4
0.2
- - -
- - -
- - -
9%
4%
23%
18%
38%
32%
52%
46%
66%
61%
81%
75%
95%
89%