Setting The Minimum System Temperature; Restoring Factory Settings - Viessmann VITOLIGNO 300-C Operating Instructions For The System User

Pellet boiler, 60 to 101 kw, with weather-compensated ecotronic boiler and heating circuit control unit
Table of Contents

Advertisement

Setting the minimum system temperature

Note
Only available, if this value was enabled in the code.
Notify your heating contractor if required.
Set a value according to the minimum required tem-
perature for the heating system. When the temperature
falls below this value, the boiler or the additional heat
generator starts.
Press the following keys:
1.
for the "Extended menu".
å

Restoring factory settings

You can individually restore all modified values for
each heating circuit to their factory setting.
Press the following keys:
1.
for the "Extended menu".
å
2.
/
for "Settings".
|
~
3.
to confirm.
d
4.
/
for "Standard setting".
|
~
5.
to confirm.
d
6.
/
for selecting the required parameter group.
|
~
The parameter groups available are "Gen-
eral", "Heating" or "DHW".
Select the required heating circuit under
"Heating" with
7.
to confirm.
d
8.
/
for "Yes".
|
~
9.
to confirm.
d
The following settings and values of the selected
parameter group are reset:
Set room temperature
Set DHW temperature
Time program for central heating
Time program for DHW heating
Time program for DHW circulation pump
Party mode is deleted
Economy mode is deleted
Holiday program is deleted
Heating curve slope and level
/
and continue.
Ù
Ú
2.
/
for "Boiler".
|
~
3.
to confirm.
d
4.
/
for "Min set system temp".
|
~
5.
to confirm.
d
6.
/
for the required temperature.
|
~
7.
to confirm.
d
Further adjustments
37