Viessmann VITOLIGNO 300-C Operating Instructions For The System User page 47

Pellet boiler, 60 to 101 kw, with weather-compensated ecotronic boiler and heating circuit control unit
Table of Contents

Advertisement

Emptying the ash box
C
A
B
2.
1.
Fig. 40
Danger
Severe burns due to hot surfaces
Only perform cleaning work when the boiler is
cold.
Switch OFF the boiler.
1. Press and hold spring clip
2. Pull up locking latch
3. Flip clamping clip
C
(cont.)
4.
3.
.
A
.
B
to the side.
5.
D
E
6.
4. Pull ash box approx. 15 centimetres forwards.
5. Pull and hold pin
6. Pull ash partition
until pin
engages in the next hole.
D
7. Remove the ash box. Empty all ash.
Maintenance
D
.
in the direction of the arrow
E
47