Heating Curve - Viessmann VITOLIGNO 300-C Operating Instructions For The System User

Pellet boiler, 60 to 101 kw, with weather-compensated ecotronic boiler and heating circuit control unit
Table of Contents

Advertisement

Central heating
Time program
(cont.)
Restoring time phases to factory settings
Note
The time phases are only restored to the factory set-
tings when you reset all settings for the selected heat-
ing circuits.

Heating curve

Adjusting the heating curves
If the room temperature does not meet your require-
ments for a prolonged period of time you can alter
the heating characteristics.
You alter the characteristics by changing the slope
and level of the heating curve. For more information
regarding the heating curve, see page 21.
Please observe the modified heating characteristics
over several days (if possible, wait for a major
change in the weather) before making further adjust-
ments.
Heating characteristics
The living space is too cold during the
cold season.
The living space is too hot during the
cold season.
The living space is too cold during
spring/autumn and during the cold
season.
The living space is too hot during
spring/autumn and during the cold
season.
The living space is too cold during
spring/autumn, but warm enough dur-
ing winter.
The living space is too hot during
spring/autumn, but warm enough dur-
ing winter.
Press the following keys:
1.
for the "Extended menu".
å
2.
/
to select "Heating".
|
~
20
The steps for restoring factory settings can be found
on page 37.
Changing slope and level
For assistance, use the following table.
Action
Adjust the heating curve slope to the next
highest value (e.g. 1.5).
Adjust the heating curve slope to the next
lowest value (e.g. 1.3).
Adjust the heating curve level to a higher
value (e.g. +3).
Adjust the heating curve level to a lower
value (e.g.
3).
Adjust the heating curve slope to the next
lower value and the level to a higher val-
ue.
Set the heating curve slope to the next
higher value and the level to a lower val-
ue.
3.
d
4.
/
Ù
Ú
Example
Slope
Level
Slope
Level
Slope
Level
Slope
Level
Slope
Level
Slope
Level
to confirm.
to select "Heating circuit 1" (HC1), "Heat-
ing circuit 2" (HC2), "Heating circuit 3"
(HC3) or "Heating circuit 4" (HC4, if
installed).
1.5
0 K
1.3
0 K
1.4
3 K
1.4
-3 K
1.3
3 K
1.5
-3 K