Operating Faults; Errors - Cause - Remedy - Kohler KD45V20 Operation And Maintenance Manual

Table of Contents

Advertisement

Malfunction / error
The starter does not turn over.
The starter turns over slowly.
KD45V20 33521030001_4_1 en 2018-08-01

4 Operating faults

Please consult the table "Errors – Cause – Remedy" for certain engine problems
with possible causes and corrective action.
Information
Engine errors are shown on the diagnosis and service tool as an error code for
diagnostic purposes.
The following table shows basic logical steps to diagnose the problem:
– Familiarize yourself with the engine and related systems.
– Investigate the problem carefully.
– Correlate the symptoms with your current knowledge of the engine and
systems.
– Diagnose the problem, starting with the most obvious assumptions.
– Carry out detailed analyses before taking the engine apart.
– Identify the causes and thoroughly perform any repair work.
After the repair:
– run the engine in accordance with the User Manual.
– Check that the causes have been eliminated.
– Cancel the fault.
4.1 Errors – Cause – Remedy
Cause
The main fuse has blown.
The battery connections are loose or
corroded.
The battery voltage is too low.
The starter's circuit is faulty or the
contacts are corroded.
The starter is faulty.
The battery voltage is too low.
The battery connections are loose or
corroded.
The outside temperature is too low.
© 2018 by Kohler Co. All rights reserved.
Remedy
Replace the fuse.
Clean and tighten the loose
connections.
Charge or replace the battery.
Contact KOHLER Co.
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
Charge or replace the battery.
Clean and tighten the loose
connections.
Take appropriate action for Winter
operation.
33

Advertisement

Table of Contents
loading

Table of Contents