Kohler KD45V20 Operation And Maintenance Manual page 34

Table of Contents

Advertisement

Operating faults
Errors – Cause – Remedy
Malfunction / error
The Diesel engine cannot be started
and/or stops again immediately.
Trouble starting the Diesel engine.
The Diesel engine switches off
suddenly.
34
Cause
The fuel tank is empty.
The fuel filter is blocked.
The fuel line, pre-cleaner or screen
in the fuel tank are blocked.
There is a leak in the fuel system or
filter.
The outside temperature is too low.
There is a leak in the low-pressure
circuit or the pressure is too low.
The Diesel engine's compression is
too low.
The heating flange is faulty (at low
temperatures).
The power supply has been
interrupted.
There is a leak in the low-pressure
circuit or the pressure is too low.
There is a fault in the electronic
system.
© 2018 by Kohler Co. All rights reserved.
Operation and Maintenance Manual
Remedy
Refuel and vent the fuel system.
Replace the fuel filter.
Clean and vent the fuel system.
Seal this and vent the system.
Take appropriate action for Winter
operation.
Carry out a leak test (visual
inspection); contact KOHLER Co. to
have the engine checked.
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
Read out the error memory of the
engine control unit. Contact
KOHLER Co.
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
Carry out a leak test (visual
inspection); contact KOHLER Co. to
have the engine checked.
Read out the error memory of the
engine control unit. Contact
KOHLER Co.
KD45V20 33521030001_4_1 en 2018-08-01

Advertisement

Table of Contents
loading

Table of Contents