Operating faults
Errors – Cause – Remedy
Malfunction / error
The charge air temperature is too
high.
The charge air pressure is too low.
38
Cause
The charge air cooler is dirty.
The inlet air temperature is too high. Check the fan, air supply and
The air filter is blocked.
The charge air cooler is dirty.
The turbocharger outlet is faulty.
© 2018 by Kohler Co. All rights reserved.
Operation and Maintenance Manual
Remedy
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
breather.
Check the air filter's service display,
if equipped.
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
Contact your nearest authorized
Kohler service representative. See
"Service Assistance" section.
KD45V20 33521030001_4_1 en 2018-08-01