No.
Part name
P.C.Board
1. Detachment
6
(for
1) Carry out work 1 of
compressor
drive)
Never disassemble the inverter for 3
MCC-1627
minutes after power has been turned off
because an electric shock may be caused.
2) Take off screw 4 pcs. and life the
PL-FIX-CDB up.
3) Take off screw for fixing the P.C.Board
(for compressor drive) with HEAT-SINK.
4) Take off the P.C.Board (for compressor
drive) from 3 PCB mounts.
5) Take off all the connectors and faston
terminals connected to the P.C.Board.
CN11 :
CN852 :
CN07,08 : Reactor (1P: faston terminal)
CN200,201,202: Compressor (1P: faston
2. Attachment
1) Mount the individual components in
Be sure that all the connectors are
connected correctly and securely inserted.
If the components on the P.C.board were
bent during this procedure, straighten
them so they do not touch other parts.
Procedure
.
5
WARNING
*Take off connectors by pulling the
connector body. Do not pull the wire.
*connectors should be remove after
unlocking the housing section.
Relay intput (2P: White)
UART Communication (6P:
Red)
terminal)
the opposite procedure to that during
detachment.
CAUTION
4 Screw for P.C.Board(MCC-1627)
- 91 -
Remarks
Screw