LOCATION
INDOOR UNIT
•
Ensure the indoor unit is located away
from heat or steam�
•
Ensure the indoor unit is located so it can
be accessed for service and replacement�
•
Ensure the indoor unit is located so
condensate can be drained away�
•
Select a location where the indoor unit
can be securely mounted�
•
The
clearances
shown
maintained�
OUTDOOR UNIT
•
Select the location where exposure
to direct sunlight and strong wind are
minimised�
•
Select the location where the outdoor unit
can be securely mounted�
•
Select the location where the noise and
air flow will not cause nuisance.
•
Ensure there are no obstructions in the
air flow path.
•
Ensure the out door unit is located so
it can be accessed
replacement�
•
Do not place animals and plants near the
air discharge�
•
The
clearances
shown
maintained�
PIPE LENGTH & ELEVATION LIMITS
Models
mm
RINV25RC
Ø9.52
RINV34RC
Ø9.52
RINV51RC
Ø12.7
RINV70RC
Ø15.88
Rinnai
MUST
BE
for service and
MUST
BE
Pipe Size
Gas
Liquid
inch
mm
3/8
Ø6.35
3/8
Ø6.35
1/2
Ø6.35
5/8
Ø6.35
Indoor unit
Indoor unit
X
X
Y
Y
Outdoor unit
Outdoor unit
1 0 0 0
1 5 0
(All dimensions in mm)
Standard
Length
inch
m
1/4
5
1/4
5
1/4
5
1/4
5
Outdoor unit
Outdoor unit
X
X
Indoor unit
Indoor unit
8
1 5 0
3 0 0
0
1 0 0
Maximum
Maximum
Length - X
Height -Y
m
m
15
8
15
8
20
10
25
10
Y
Y
1 0 0
1 0 0
3 0 0
Additional
Refrigerant
g/m
20
25
30
40
Split AC IM