INDOOR UNIT

Wall Mounting Plate

1�
The wall or structure on which the units are to be mounted must be capable of supporting the weight of the
appliance and the associated pipe-work�
2�
Fix the mounting plate on to the wall, ensuring that it is both level and firmly mounted with the appropriate
fixings.
DO NOT install the unit in a place where electrical wiring or conduits are located�
CAUTION
2.5 kW / 3.4 kW
A
B
C
300
800
168

Wall Penetration

Drill a Ø70mm wall penetration through the wall with a 2° to 4° fall to the outside wall�

Drain Pipe

1�
Connect the drain pipe to the drain hose outlet of the indoor unit,
2�
Bind the joint with PVC insulation tape (not supplied)�
Rinnai
B
Wall Mounting Plate Positioning Dimensions (mm)
D
E
A
B
96
64
315
970
INSIDE
D
Ø70
5.2 kW
C
D
E
195
45
57
2° to 4° fall
OUTSIDE
9

INSTALLATION

C
A
E
7.0 kW
A
B
C
D
330
1100
214
56
E
55
Split AC IM