This appliance shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturers instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RINV34RC

  • Page 1 Installation Manual Split Type Wall Mounted Air Conditioner Models: RINV25RC / RINV34RC / RINV51RC / RINV70RC This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000 • Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person.
  • Page 2 This page is intentionally blank Rinnai Split AC IM...
  • Page 3: Table Of Contents

    Connecting Vapour / Liquid Pipes To Indoor & Outdoor Units ���������������������������������������������������������������������� 13 Air purging & Leakage Test �������������������������������������������������������������������������������������������������������������������������� 14 Evacuation Vacuum Method / Leak Test ������������������������������������������������������������������������������������������������������ 14 Adding refrigerant for longer line length ������������������������������������������������������������������������������������������������������� 14 Final Checklist �������������������������������������������������������������������������������������������������������������������������������������������������� 15 Contacts Rinnai Split AC IM...
  • Page 4: Warnings And Important Information

    The table below indicates the temperature ranges the air conditioner can be operated within� MINIMUM MAXIMUM MODE TEMPERATURE SOURCE OPERATION OPERATION TEMPERATURE TEMPERATURE Adjustable inside temperature 16°C 32°C Cooling / Heating Ambient outside temperature -12°C 47°C Rinnai Split AC IM...
  • Page 5 Use a standard circuit breaker and fuse conforming with the rating of the appliances� Model Circuit Breaker (Amps) RINV25RC RINV34RC RINV51RC RINV70RC The unit must be earthed in accordance with local regulations� Connect all wiring tightly� Failure to do so may result in electric shock or product failure�...
  • Page 6 DO NOT mix the batteries for the remote control with other types of batteries or mix new batteries with used batteries� Failure to do so may result in product failure� STOP using the remote control if there is a battery fluid leak. Rinnai Split AC IM...
  • Page 7: Installation General

    10� Outdoor unit air inlet (on rear & left side of unit) 11� Outdoor unit discharge protective grille front unit) WEIGHTS & DIMENSIONS Model RINV25RC RINV34RC RINV51RC RINV70RC Indoor Weight (kg) Outdoor 27.5 Indoor 1100 Dimensions (mm) Outdoor...
  • Page 8: Location

    Standard Maximum Maximum Additional Liquid Length Length - X Height -Y Refrigerant Models inch inch RINV25RC Ø9.52 Ø6.35 RINV34RC Ø9.52 Ø6.35 RINV51RC Ø12.7 Ø6.35 RINV70RC Ø15.88 Ø6.35 Outdoor unit Outdoor unit Indoor unit Indoor unit Outdoor unit Outdoor unit Indoor unit...
  • Page 9: Installation

    Drill a Ø70mm wall penetration through the wall with a 2° to 4° fall to the outside wall� INSIDE 2° to 4° fall OUTSIDE Drain Pipe 1� Connect the drain pipe to the drain hose outlet of the indoor unit, 2� Bind the joint with PVC insulation tape (not supplied)� Rinnai Split AC IM...
  • Page 10: Electrical Connections

    NOTE 2. Unscrew the rubber plug from the alternate drainage discharge connection point. 3. Clip the drainage hose into the alternate discharge connection point. 4. Screw the rubber plug into the unused drainage discharge connection point. Rinnai Split AC IM...
  • Page 11: Outdoor Unit

    Remove the wiring cover� 2� Secure the electrical cable(s) and power cable onto the control board with the cable clip� 3� Connect the cables as shown on the drawing below� Wiring cover 4� Re-install the wiring cover� Rinnai Split AC IM...
  • Page 12: Dred Connection (Optional)

    Insert the barbed elbow into the drainage point of the outdoor unit as shown� A drainage hose (installer to supply) will need to be fitted. Drainage of the condensate must conform with all local regulations and municipal building codes including local OH&S requirements. IMPORTANT Rinnai Split AC IM...
  • Page 13: Refrigerant Pipes

    Ø 5/8" 75 Nm Indoor Unit Outdoor Unit Vapour pipe Liquid pipe Ensure the joint nut is tightened firmly to avoid leakage. Ensure that both the connections and the refrigerant pipes are wrapped with insulation material. CAUTION Rinnai Split AC IM...
  • Page 14: Air Purging & Leakage Test

    It is very easy to overcharge, take caution in charging refrigerant liquid and keep your eye on the scales to avoid Vacuum CAUTION overcharging the unit. Pump Take care not to discharge refrigerant into the atmosphere during installation, re-installation, repair or service. Rinnai Split AC IM...
  • Page 15: Final Checklist

    No cooling or heating Is the end user fully aware of the operating procedure? Incorrect operation If you have answered no to any of the above, you must check and correct before appliance hand-over to customer. Rinnai Split AC IM...
  • Page 16: Contacts

    Braeside, Victoria 3195 For further information visit: www.rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 1 years.